Low-frequency SEEG features retained recall-decoding performance in 18 patients; high-gamma-only features performed worse
This offline analysis tested whether within-patient SEEG word-recall decoders retained performance when restricted to lower frequencies. It used archived per-word Morlet log-power features from 18 patients in the FR1 delayed free-recall task (OpenNeuro ds004789 v3.1.0, session 0; bipolar SEEG recorded at 500–1000 Hz). Balanced L2 logistic regression (C = 7.2e-4) was evaluated with leave-one-list-out prediction for five frequency sets. Under a prespecified rule, features at or below 80, 40, and 13 Hz were sufficient relative to all eight frequencies: median AUCs were 0.673, 0.662, and 0.657 versus 0.669 for all frequencies; Holm-adjusted p values were at least 0.46, and the group-median retained fractions of above-chance AUC were 1.02, 0.96, and 0.93. The 80+140 Hz set was not sufficient (median AUC 0.631; Holm p = 0.0006; 0.78 retained fraction) and had lower AUC than all frequencies in 16 of 18 patients. Within-serial-position results showed the same pattern. “Sufficient” is a fixed plan rule, not a formal equivalence test; with 18 patients, a small loss (about 0.01 AUC) for the 13 Hz set remains possible. The features came from 500–1000 Hz recordings rather than a 250 Hz implant, and filtering, sampling, and contact count may change performance. The analysis was offline, used one session per patient, and classified recall versus no recall. The planned single-frequency, leave-one-frequency-out, and penalty-sensitivity analyses were not run because of the 45-minute, one-CPU run limit.
SEEG · word recall · memory · frequency bands · AUC · logistic regression · neural decoding · OpenNeuro
References
3- usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a
We use its archived band-power features, patient selection and W_chan decoder code without change.
- usesFixed L2 penalty outperforms per-patient tuning for SEEG recall decoding in 18 FR1 patients sci:sha256:ac34e9f829a95f5eed29959d7e06e96828d7691379f8f036f5e5ee3868057afb
It supports the fixed penalty C = 7.2e-4 that we use for all frequency sets.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
Source dataset for the FR1 delayed free-recall session and archived SEEG features analyzed in this publication.
Cited by
1 publicationPublic catalog entries on Sciscape.
- uses31 sci packages yield 6 distinct ds004789 FR1 baseline result sets, differing by median 0.044–0.066 AUC per patient across 17 patients
We used column ALL of results/per_patient.csv as the baseline AUC (family F1).