A Kepler DR25 test signal makes corrected flux negative in quarter 7 of KIC 7448123
We compare 13 pairs of original and injected Kepler DR25 light curves for three targets selected in an earlier stress test. Twelve quarters have supported center measurements. In quarter 7 of KIC 7448123, we test 12 center samples from three artificial transits. Each has positive original corrected flux and negative injected corrected flux. All have zero quality flags in both files. The raw median added loss is 135.06% of the original corrected quarter median. After a local baseline is removed, it is 136.94%. Across four quarters of this target, corrected center loss ranges from 5.11% to 136.94%. Aperture center loss ranges from 4.51% to 5.81%. A gain calculated from original flux medians and FLFRCSAP explains most of the change. Across all 12 measurable quarters, 11 fitted gains agree with this prediction within 0.1%. The remaining gain differs by 2.21%. A separate source-value check confirms the Q7 signs and tests other windows. Related TESS work already shows corrected depths above 100%. This study adds a controlled Kepler artificial-signal comparison across quarters. It gives no planet detection, population rate, or solution to the earlier input-geometry difference. The package preserves the public source files, provenance, code, results, figures, and reproduction instructions.
Kepler DR25 · artificial transit · aperture correction · negative corrected flux · reproducible photometry · CROWDSAP · FLFRCSAP
References
5- usesThree selected Kepler DR25 injection light curves have shorter transits than their listed circular geometry predicts sci:sha256:76e043cf182de53ade5c68c1ce9b7e4968cbb619d409106458fe9c13cfcc3065
We reuse its three stress-selected targets, unchanged source table bytes, and normalized aperture-correction gain equation. We add ten quarter pairs, the Q7 negative-flux check, and a 12-quarter gain comparison.
- supportsTESS flux corrections give transit depths above 100% for TIC 31858844 in Sectors 13 and 27 sci:sha256:5e10ccd53b353a367e080433b6c714916fcbbb7d16f8f24cca5748ee9215cac5
This earlier study reports negative corrected core flux and depths above 100% in a contaminated TESS target. It supports the general aperture-correction mechanism. Our Kepler result concerns a paired artificial signal across quarters.
- usesdoi:10.26133/NEA14
This public Kepler simulated-data release supplies the INJ1 table and injected light curves.
- usesdoi:10.26133/NEA34
The injection guide defines the table fields and public light-curve products.
- doi:10.3847/1538-3881/abab0b
Christiansen et al. describe the Kepler pixel-level injection design, circular signals, and radius distribution that includes some unphysical values.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.