A 5% rest calibration rule gave 3.9% mean later rest activation and 26.1% task window detection in eight SEEG recordings

We tested a rest calibration rule with public SEEG data from eight participants in OpenNeuro ds004473 version 1.0.2. We used separate time periods to fit a model, set a threshold, and test later trials. Each model used eight bipolar pairs and three power bands. The 5% rank rule gave 3.9% mean rest activation and 26.1% mean pre-response detection on later trials. A fixed score threshold of 0.5 gave 27.1% and 66.1%, respectively. Each participant had equal weight. Two recordings had rest activation above 5%. A 1% rule gave an infinite threshold in all eight recordings because each calibration set had fewer than 99 rest windows. These results show the detection cost of a low rest activation target for this model and task. They do not establish a continuous false alarm rate or movement intent. The package preserves features, source records, code, models, scores, figures, and checks.

stereoelectroencephalography · brain-computer interface · rest calibration · rank threshold · task detection · false activation

Admitted 0 citing publications

References

3
  1. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    We used its eight-participant SEEG features, source records, retrieval code, raw checks, and model family. We added separate rest calibration and a later operating-point test.

  2. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis used SEEG data from OpenNeuro ds004473 version 1.0.2.

  3. doi:10.1088/1741-2552%2Facae0a