At 6 mA, pulse-split SEEG direction agreement exceeded a before-pulse control in five patients but weakened across odd and even pulses
We tested whether the stronger measured direction of a reciprocal SEEG pair remained stronger in separate pulse sets. We used public OpenNeuro ds004457 version 1.0.2. Fixed metadata rules selected 69 stimulation sites, 111 receiving contacts, and 329 reciprocal pairs in five patients. At each site, we used the same two contacts for stimulation and bipolar recording. Stimulation current was 6 mA. The late window was about 50–250 ms. The first and last five pulses gave 65.5% mean direction agreement after pulses and 54.5% in a matched control before pulses. The equal patient mean difference was 11.0 percentage points. Four of five patient differences were positive. The exact two-sided patient sign-flip p value was 0.1250. The primary difference had a descriptive patient bootstrap interval of 2.6 to 18.7 points. The planned odd and even pulse split gave a mean excess of 2.1 points, with p = 0.8750. Raw energy gave high agreement in both after and before windows. The result depends on pulse split and baseline choice. Five patients limit group inference. The package contains pulse windows, raw source hashes, code, all pair scores, and fixed checks. The result concerns recorded voltage strength order. It does not establish anatomical connection direction or clinical value.
stereo-EEG · electrical stimulation · direction agreement · corticocortical evoked potentials · pulse reproducibility · normalized voltage · OpenNeuro
References
4- usesThe mean patient median log variance ratio was +0.505 dB after 6 mA pulses in five ds004457 SEEG patients with separate window means sci:sha256:b4dde54e7944e6b5eee7a52e9215361e77037f009b3ca8103ca6d752a091f68d
We used this study's retrieval and raw-bin audit example for the same source cohort. Its report also informed separate time-mean removal in each window. We selected new contacts and extracted new raw windows. Its saved arrays and result values are not analysis inputs.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Raw SEEG signals and source metadata from ds004457 version 1.0.2 were used to build the compact pulse windows and analyze matched reciprocal stimulation pairs.
- usesdoi:10.1523/JNEUROSCI.1325-22.2023
This is the source study for the SEEG cohort and dataset.
- doi:10.1523/JNEUROSCI.4289-13.2014
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesTime-centered 50 to 250 ms SEEG windows showed no clear increase in early-to-late change after stimulation in five patients
We used its early-and-late versus interleaved pulse comparisons as context for the choice of pulse-order question. We test voltage waveform distances rather than response direction agreement. The five patients are shared; this is not an independent replication.