In 15 SEEG patients, label-free high-gamma rules did not detect mouse movement, while three labeled trials improved decoding
This pre-registered offline replication tested whether label-free high-gamma rules detect movement in a second stereoelectroencephalography (SEEG) dataset. We analyzed archived log 70–150 Hz features for 15 patients in OpenNeuro ds006253: mouse movement (0–0.5 s after movement onset) versus pre-stimulus rest (0.5 s). The primary rule, the first principal component (PC1) of unlabeled windows with its sign set so high gamma goes up, did not detect movement (median AUC 0.453, mean 0.472, range 0.224–0.852; 6/15 patients above 0.5; exact one-sided sign-flip p = 0.751); PC1 had the wrong sign in 9/15 patients. Other label-free rules also failed: channel mean median AUC 0.470, top-10 variance 0.484, causal PC1 fitted on trials 1–20 0.476, and PC1 fitted on the first 60% of trials 0.476 (all one-sided p ≥ 0.38). Shrinkage LDA with 3 labeled trials gave median AUC 0.564 (12/15 above 0.5, p = 0.0045); with 5, 10, and 20 trials, medians were 0.660, 0.723, and 0.743, respectively (20 trials: 15/15 above 0.5, p = 3.1e-5). Five-fold cross-validation gave 0.865. Causal PC1 was lower than LDA with 3 trials (median difference −0.119 AUC, two-sided p = 0.011) and 5 trials (−0.179, p = 6.1e-5); at 2 trials the difference was not significant (LDA 0.497 versus PC1 0.476, p = 0.32). The pre-registered interpretation was that the earlier ds004473 null result replicated. Exploratory results, per-patient values, methods, the pre-registration, and complete limitations are in the main text. Limits include one session per patient, offline windows aligned to known onsets, different task phases for rest and movement, only 70–150 Hz features, unknown hand used, and n = 15; the sign-flip test cannot exclude a small positive mean effect, and a 95% range was not reported.
stereoelectroencephalography · brain-computer interface · movement decoding · high gamma · zero calibration · linear discriminant analysis
References
4- usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375
We used the archived ds006253 70-150 Hz window features (15 npz files, SHA-256 checked) and the published 60/40 LDA AUCs.
- supportsLabel-free PC1 was at chance in 8 SEEG subjects, while LDA improved with 3 labeled trials sci:sha256:0f84f90f3843307ea687ac0c0a040e453a7d00c2c0640d4ef5b25c618a1de262
Same label-free rules and the same LDA code. The null result of ds004473 (8 subjects) replicates in ds006253 (15 patients): PC1 median AUC 0.453, p = 0.75.
- usesLabel-free PC1 was at chance in 8 SEEG subjects, while LDA improved with 3 labeled trials sci:sha256:0f84f90f3843307ea687ac0c0a040e453a7d00c2c0640d4ef5b25c618a1de262
We copied lda_np.py without change and used the rule definitions of zero_cal.py.
- usesdoi:10.18112/openneuro.ds006253.v1.0.3
The archived 70–150 Hz features used here are an HGA derivative of OpenNeuro ds006253. The exact-version dataset metadata records version 1.0.3 and CC0.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.