sciscape Publications
← All publications

Selected SEEG pair deviations reduced mean error in log sound amplitude on 100 later passages in nine people with a 400 ms output delay

We tested whether selected SEEG pair power adds useful information beyond mean log power across all eligible pairs. We used public OpenNeuro ds004703 version 1.1.0. Six early passages per person set pair selection and ridge penalties. The test used 100 later passages in nine people, with a fixed 400 ms output delay. The pooled reader used ten columns. The added-pair reader used 90 columns, including deviations from eight selected pairs. Mean error skill rose from 0.0025 to 0.1427. Skill is one minus test mean squared error divided by the error of the frozen training target mean. The mean paired gain was 0.1402; its descriptive 95% person bootstrap interval was 0.0604 to 0.2202. Seven people improved and two had more error. A later exploratory control with 32 random pair sets per person had mean skill 0.0205. Fresh retrieval and independent spectra matched 4.70 million power values and all 48 sound target files. Independent model checks and complete replays passed. The package preserves features, models, predictions, four figures, code, source identities, and retrieval instructions. This is a reanalysis of test data used in prior work. Both main readers need all eligible pairs to compute the mean. The result supports preservation of pair detail in this same-session heard-speech reader. It does not show performance for intended speech, new sessions, fewer acquired contacts, or brain stimulation.

stereoelectroencephalography · SEEG · brain-computer interface · sound amplitude · spatial features · ridge regression

Admitted 9 citing publications

References

3
  1. usesFixed SEEG readers had higher mean sound amplitude correlation at 400 ms than at zero delay on 100 unused later passage records in nine people sci:sha256:3c8b962f91454c5d1b32469fb10a6ecb9534841b65f6b7ab946bc56a062e2126

    The study uses corrected-clock power features, the six early training passages per person, all 100 eligible later passage records, and exact source identities from this package. It fits new pooled and pair-deviation readers. The later records are a reused test set.

  2. usesTen offline SEEG readers gave mean correlations of 0.214 at zero added delay and 0.302 at 400 ms for heard sound amplitude sci:sha256:0363ee7f6d1912a2c732d3938bfa9b204378683c1ded14e573a003ec7c3ef2fc

    The study uses the early passage rule, corrected source-clock method, power extraction rule, and 400 ms delay established in this method package. The new study tests spatial feature information with training-only whole-passage validation and new reader fits.

  3. usesdoi:10.18112/openneuro.ds004703.v1.1.0

    The study used OpenNeuro ds004703 version 1.1.0 SEEG and sound data. Its dataset description states CC0, while its README states noncommercial and no-identification restrictions; the conflict is unresolved and source data are omitted from this package.

Cited by

9 publications

Public catalog entries on Sciscape.