Output phase tests gave excess beta phase slope index flags under independent contact phases in two public SEEG spectral models
We tested phase slope index (PSI) phase tests with fixed spectra from two public SEEG records. The model kept recorded-contact magnitudes and drew independent contact, segment, and frequency phases. The sample had 28 contact quartets in total. Each record had 200 two-second Hann segments. A flag was a test rejection at the 5 percent level. In the primary 13–30 Hz band, phases drawn after bipolar subtraction gave 6.98 percent flags with equal patient weights. Phases drawn before subtraction gave 4.98 percent. Their paired difference was 2.01 percentage points, with a Monte Carlo standard error of 0.22 points. The separate-contact control gave 5.11 percent output flags. We proved zero population PSI and exact finite-sample variance identities. Equal-power checks showed conservative output tests at small segment counts and excess flags at large counts. The package preserves exact inputs, all primary null scores, source locks, code, results, and checks. The result concerns this conditional spectral model. It does not estimate neural or clinical error rates.
phase slope index · surrogate testing · bipolar montage · stereoelectroencephalography · phase randomization · spectral connectivity · Monte Carlo calibration
References
3- usesOutput phase tests reduced imaginary coherency rejection under independent contact phases in two public SEEG spectral benchmarks sci:sha256:209c743cb5f39895e097dc7c4a2aa7577931a66bdaa356427edd01e541cdb0e0
Used the prior comparison of contact and output phase tests to choose a PSI calibration question. No prior code or numerical input was reused. The present segment-averaged PSI estimator differs from the earlier pooled imaginary coherency estimator. Both studies use the same two records.
- usesdoi:10.18112/openneuro.ds005670.v1.0.0
Source data used: OpenNeuro ds005670 snapshot 1.0.0. The publication records the source URL, author, version, DOI, and CC0 license.
- doi:10.1103/PhysRevLett.100.234101
Background paper introducing the phase slope index discussed in the publication.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesOutput shifts gave excess beta PSI rejections for shared contacts under independent contact segment rotations in two SEEG records
We used the quartet selection rule, native EDF reader, source locks, BIDS metadata, and small reader fixtures. We downloaded the raw files again and extracted complex coefficients. We tested recorded contact segment rotations instead of independent phases in each frequency bin. The study uses the same two patients.