In 21 RepFR1 patients, events.tsv sample was word-locked and onset was not
A memory brain-computer interface must determine during word encoding whether a patient will later recall a word. Three library studies of RepFR1 SEEG data from OpenNeuro ds005411 found no such recall read-out; one reported mean held-out AUC 0.498 in 21 patients. We tested whether the events.tsv sample column (EDF sample index) or BIDS onset column (seconds) was locked to words. Before reading neural data, we wrote and hashed a plan. In 21 patients, we compared 70–150 Hz power at both candidate times for 81 words per patient, using the first three lists with a recall. The sample time had more responsive channels in 16 patients, onset in none, and five tied (mean fraction 4.04% vs 0.41%; exact two-sided sign-flip p = 3.1e-5). Median |t| was larger at sample in 18 patients (mean 0.88 vs 0.73; p = 7.1e-4). The response at sample peaked 0.3–0.4 s after the word; onset had no word-locked response. Thus sample was word-locked, and the archived features used by study 02694702 had valid timing. The plan therefore did not call for re-extracting features at onset, and this was not done. In 9 patients the columns also ran at different rates (4.5–52 ppm), so a constant onset correction would not suffice; the difference changed by up to 0.44 s over lists 0–9. The study tested only three lists per patient, resolves alignment to about 0.1–0.2 s, included all bipolar channels (including ECoG-typed channels), and did not test new recall decoders. The archived source files do not establish an exact OpenNeuro release; the README preserves the source URL and file hashes.
RepFR1 · SEEG · BIDS · event timing · word encoding · high gamma · OpenNeuro · memory · electrophysiology
References
4- supportsBand power did not predict later free recall in 21 RepFR1 patients sci:sha256:9274cb2c31d419cc4594fbb1d5aaed16033a5aac18e57488115469468af3e0f4
Its features were read at the sample column. We show that sample is word-locked in all its 21 patients and onset is not. Thus its null read-out did not come from misaligned epochs.
- usesBand power did not predict later free recall in 21 RepFR1 patients sci:sha256:9274cb2c31d419cc4594fbb1d5aaed16033a5aac18e57488115469468af3e0f4
We use its events.tsv files, its session provenance (SHA-256 checked), its patient set and its feature code as the reference for the time column.
- supportsSEEG band power did not predict later free recall above chance in five RepFR1 patients sci:sha256:88f45798b572316e24951c4d2798e2b775c5041a9dcc73259855b728c0add782
Its 5 patients are in our test. Its code reads at sample, which we show is the word-locked column.
- supportsSEEG band power was near chance for repetition decoding after serial-position control in four patients sci:sha256:86fd8c699c922fd9236cb21b6d062ee720c07cce20b7ebde410e475b094e2572
Its code reads at sample. We show that sample, not onset, is word-locked in ds005411. This agrees with its own high-gamma control.