A session-0 SEEG recall decoder predicted session-1 recall above chance in seven patients
This offline study tested whether an individual-patient decoder trained on FR1 session-0 data predicted word recall in session 1 without session-1 labels. Seven of nine patients with recordings in both sessions met the pre-registered inclusion rule. Using common bipolar SEEG channels, within-session z-scored log10 Morlet power at eight frequencies, and the archived W_chan L2 logistic decoder, cross-session prediction had median AUC 0.622; all seven patients were above chance (exact one-sided Wilcoxon p = 0.0078; Holm-adjusted p = 0.023). Cross-session AUC was not significantly different from session-1 leave-one-list-out AUC (median difference −0.033, p = 0.22), and adding session 0 to session-1 training did not significantly change AUC (median difference +0.016, p = 0.38). These null tests do not establish equality. Cross-session AUC was below session-0 leave-one-list-out AUC in all seven patients (median difference −0.058, p = 0.016). A within-serial-position analysis was also above chance (median AUC 0.608, p = 0.016). The study includes one session pair per patient, one decoder and feature set, and offline analysis; its findings are limited to seven patients.
SEEG · word recall · memory · brain-computer interface · cross-session decoding · AUC · OpenNeuro · FR1
References
4- supportsCross-day SEEG decoding preserved AUC but worsened probability calibration in 10 subjects sci:sha256:c0fcc8f250f1cda538614010f79e3156a9fc648b77fa6330be2bb1014c5ae2c2
Their ds004752 result that a decoder from another day keeps most of its AUC agrees with this FR1 word-recall result in a different task and dataset.
- supportsPooling earlier sessions did not improve new-session SEEG load decoding over the latest session sci:sha256:6bb80018bacd7f34ffb73a0bbb89e2eb44676ae924aff2e4248e4c33a9b8d05e
Their ds004752 result that more earlier-session data did not improve a new session agrees with the null POOLED-minus-WITHIN result here for FR1.
- usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a
Uses its archived FR1 session-0 features, its feature-extraction code (session made an argument) and its W_chan decoder code without change.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
Session-1 FR1 recordings were sourced from OpenNeuro ds004789 version 3.1.0.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.