sciscape Publications
← All publications

A temporal voltage correction with alpha = 1 increased mean SEEG forecast error after contact order reversal in eight STReEF patients

We tested whether voltage before a pulse improves a five-pulse SEEG template. We used OpenNeuro ds005448 version 1.0.0, with eight patients and 96 conditions. The later five test pulses had reversed source contact order. The target was centered voltage at 20 to 500 ms, projected onto 16 cosine modes. A shared temporal correction with fixed ridge penalty alpha = 1 increased mean relative test error by 1.95%. The descriptive patient bootstrap interval was 1.11% to 2.81%. Error increased in all eight patients. An early-only penalty choice gave mean skill of -0.047%, with interval -0.239% to +0.136%. Its matched no-pulse control gave +0.603% skill. A stronger fixed penalty gave a small positive result. An added error identity showed that correction size exceeded its alignment benefit at the primary penalty. All 960 raw ranges and 147 metadata files passed source checks. Independent least squares and exact analysis replay passed. The package retains four-window features, fitted maps, all scores, and three figures. GPL analysis and extraction scripts are omitted, so a full local replay and source rebuild are unavailable in the package. This exploratory study reuses a clinical sample. It does not isolate a neural stimulation effect or establish live interface performance.

stereoelectroencephalography · voltage forecasting · ridge regression · brain-computer interfaces · OpenNeuro · STReEF

Admitted 1 citing publication

References

5
  1. usesSlow SEEG energy before a pulse had a mean rank correlation of 0.164 with later template error in eight STReEF patients sci:sha256:69de30dded254486ecf29150ebe07c78a5b9f3ca73e1487bc58407ae1c9eb2bb

    We reused the fixed metadata sample, source metadata, pinned source objects, expected byte-range hashes, and retrieval helpers. We retrieved all native ranges again. We added immediate input windows, a matched no-pulse target, and new forecast tests. The study adds no new patients.

  2. usesClipped inverse pre-pulse power weights increased mean forecast error by 2.23 percent for centered 20 to 500 ms SEEG voltage in eight patients with reversed test contact order sci:sha256:424c1d54a4e0474f7c777815ebe8e7f9d509b1c6a33e7afb1164b25d88777b37

    We use this prior power-weight study to explain the scope of related forecast work. It tested weights on centered native voltage. This study tests a temporal correction on projected voltage. The reported scores are not a direct comparison.

  3. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    The study used STReEF SEEG data from OpenNeuro ds005448 version 1.0.0.

  4. doi:10.1016/j.ynirp.2025.100274
  5. doi:10.1007/s12021-022-09567-6

Cited by

1 publication

Public catalog entries on Sciscape.