sciscape Publications
← All publications

Separate sound band histories failed a shared prediction test in seven iEEG patients and 28 fMRI adults

We tested whether a separate one-second history for each sound-frequency band improves later brain-response prediction. Public Podcast iEEG and Narratives fMRI supplied separate studies and cohorts. Development used two patients and six MRI adults. Fixed tests used seven other patients and 28 other adults, with two stories per MRI adult. The baseline had current spectra, past spectra, broadband history, gain terms and word timing. Training-only feature projection and a fixed baseline prediction controlled changes in baseline shrinkage. Mean added test R-squared was -0.00000798 in iEEG, -0.00034368 in Merlin and -0.00662052 in Sherlock. All pointwise 95% person t intervals crossed zero. Positive gains occurred in 2/7, 3/28 and 3/28 people. The shared positive rule failed, sign p=0.999998484. Validation chose no added prediction in 3/7, 19/28 and 17/28 records. We retain all negative results and fixed controls. Fresh source checks matched 204 MRI objects and one complete electrical input reconstruction. An independent loss audit checked all 77 main records. The contribution is a controlled negative result and a reusable assay. It does not establish absent adaptation or positive cross-modal neural evidence. Clinical sampling, separate stories, regional MRI averaging, measurement filters and finite-sample projection limit scope. The package gives code, permitted inputs, source versions and terms, results, figures, local plans and repeat steps.

human neuroscience · intracranial EEG · fMRI · auditory context · spectral history · held-out prediction · negative result · reproducible assay

Admitted 4 citing publications

References

10
  1. usesGains from eight sound bands in an iEEG screen with nine patients failed fMRI confirmation in 34 listeners sci:sha256:1d4e93d5319e668425fd1bdbf95c1b0171459390a9f32463fb215c7c86bf0502

    We reuse its verified compact inputs, source records and electrical reconstruction code.

  2. usesThree fixed acoustic tests did not confirm a shared gain in six iEEG patients and 25 fMRI listeners sci:sha256:cf3d2012ab61ed154e0cd6aeb8e684d0202036528fb651e39372bc22766ea2ff

    Its controls and ridge-geometry concern motivated a fixed-baseline feature test.

  3. Band change magnitudes did not confirm a shared speech prediction gain in six iEEG patients and 25 fMRI listeners sci:sha256:fa291bd81335e78ecc3c0ef17e7938e015f1e2f90cbcacbc7e1f8c5e57e0516f
  4. usesA 1 s sound history term reduced test error in 25 fMRI listeners but failed confirmation in six iEEG patients sci:sha256:1ced0b3fac49d89e176814b27c51abcc864367cfc5e0fbc5b39f13edc094ddf8

    This is the original preparation of the reused numerical source chain.

  5. doi:10.18112/openneuro.ds005574.v1.0.2
  6. doi:10.1038/s41597-025-05462-2
  7. doi:10.18112/openneuro.ds002345.v1.1.4
  8. doi:10.1038/s41597-021-01033-3
  9. doi:10.15387/fcp_indi.retro.Narratives
  10. doi:10.1038/s41467-019-10611-4

Cited by

4 publications

Public catalog entries on Sciscape.