SEEG readers gave 0.515 mean AUC for transfer between images and sounds on later trials in 11 patients
We tested whether a fixed SEEG reader could separate before-onset and after-onset windows across images and sounds. We used OpenNeuro ds005415 version 1.0.0. The test used 353 later trials from 11 epilepsy patients. Each reader used eight adjacent contact pairs and raw log power in three frequency bands. The transferred readers gave mean AUC 0.515. The descriptive 95% patient bootstrap interval was 0.471 to 0.561. Local readers gave mean AUC 0.555. The paired transfer minus local difference was -0.040, with an interval of -0.085 to 0.005. The before-only transfer control gave AUC 0.499. The training label-swap reference gave p = 0.265. Transferred probability scores had mean Brier error 0.315; a constant score of 0.5 has error 0.250. A diagnostic added after the main analysis gave training AUC 0.955 and later local AUC 0.555. The package contains new power arrays, source checks, figures, predictions, models, code, and retrieval instructions. All 1,044 retained voltage ranges were fetched again and checked. A separate replay matched all analysis files. The test requires a known event onset. It does not establish a reliable BCI feedback detector or test brain stimulation.
SEEG · brain-computer interface · cross-condition transfer · AUC · clinical recordings
References
3- usesA fixed SEEG sound versus image reader gave 48.4% mean balanced accuracy across formats on later trials in 11 patients sci:sha256:ff30a8a491e06e1be6ffeac68cd458373b76e5253b9363d45f7828373a56bd26
We used its checked trial maps, fixed 11-patient cohort, pinned source objects, range hash ledger, contact pairs, metadata, raw audit ranges, source access code, and timing check code. We fetched every retained voltage range again and built new raw log power arrays for a before-versus-after response transfer question.
- usesdoi:10.18112/openneuro.ds005415.v1.0.0
The analysis used Numbers, OpenNeuro ds005415 version 1.0.0.
- doi:10.1371/journal.pone.0313155
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesSEEG power changes gave no clear gain in five-number transfer between images and sounds on later trials in ten patients with a ridge penalty of 10
This study uses its 1044 retained source trials, three-window power arrays, contact-pair maps, pinned source metadata, and byte-range ledgers. It adds new five-class ridge readers, a matched before-onset content control, and independent fit checks. Every inherited retained source range was fetched again and all power values matched exactly.