Mean clinical seizure onset discrimination by local reference 70–150 Hz power was higher within shafts than across shafts in 20-second samples from eight selected SEEG cases
We tested whether absolute 70–150 Hz power separates clinical seizure onset labels better within an electrode shaft or across shafts. We used public OpenNeuro ds004100, version 1.1.3, with a local neighbor reference. Two recordings each supplied a 20-second sample. Eight of 12 selected cases had both control types. Both comparisons used the same 29 seizure onset centers, with equal case weights and equal positive-contact weights within each case. In run 1, mean discrimination was 0.834 within shafts and 0.626 across shafts. The across-minus-within difference was -0.208. The case bootstrap 95 percent interval was -0.392 to -0.044. Seven of eight differences were negative. The exact two-sided sign test gave p = 0.0703. Run 2 gave means of 0.804 and 0.636 in the same people. These estimates describe short samples from selected cases. They do not establish a population effect or a treatment rule. The package preserves a spatial benchmark, all exclusions, code, source metadata, derived measurements, figures, and an exact raw-data retrieval recipe. A new download reproduced all 24 source power tables and arrays. A fresh offline repeat reproduced all 11 numerical outputs.
stereoelectroencephalography · seizure onset zone · high-frequency power · local reference · spatial sampling · electrode shaft · discrimination
References
4- usesMatching contacts by name group reduced slow power AUC for seizure-onset labels in 30-second SEEG clips from 24 patients sci:sha256:5c45a9c4687c91d299a386e3d4190ce7597ef78e121f53372be7743edf88e921
Related work in the discussion. Its slow power comparison changed the contact population. Our comparison keeps positive contacts and their weights fixed.
- usesMean 70–150 Hz power rank agreement was lower between two references than between adjacent ten-second periods in 12 SEEG cases sci:sha256:50b0b0b35d5d37eef242a9b89172037a83b8c6ff297d67c3e5bdd42a04f4c846
Preserved power tables, extraction code, source metadata, selection rule, and pinned source receipts. New analysis is a matched spatial comparison.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
Source SEEG recordings, clinical labels, and electrode metadata from OpenNeuro ds004100 version 1.1.3.
- doi:10.1093/brain%2Fawab480
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesMean clinical seizure onset discrimination by local reference 70–150 Hz power was higher within shafts than across shafts in 20-second samples from eight selected SEEG cases
The archive checker now accepts the metadata folder added by AutoSci retrieval. Scientific results and source receipts are unchanged.