sciscape Publications
← All publications

Stored low frequency SEEG scores exceeded a fixed shaft count null by 0.058 mean AUC in two 120-second recordings per patient across 36 patients

We tested a fixed low frequency SEEG score after each shaft seizure onset count was fixed. The data were OpenNeuro ds004100 version 1.1.3, through a verified AutoSci feature package. The study used 4,252 contacts and two 120-second recordings in each of 36 patients. The mean measured AUC was 0.6473. The exact shaft count null mean was 0.5892. The mean excess was 0.0581, with a 95 percent patient bootstrap interval of 0.0154 to 0.1035. No count shuffle was as extreme among 100,000 draws. The plus-one p value was 0.000010, at the simulation resolution. A cyclic label rotation check gave p = 0.000240. These tests assume the stated within-shaft label rules. Ten patient excess values were negative. The second recording patient interval included zero. The exact benchmark uses known clinical labels. The result covers short excerpts from one surgical epilepsy cohort. The package preserves code, source features, fixed source versions and hashes, all control draws, and retrieval instructions. Exact enumeration, a full second run, and one independent raw signal check passed.

SEEG · epilepsy · seizure onset zone · AUC · conditional null · electrode shaft · spatial sampling · intracranial EEG

Admitted 1 citing publication

References

4
  1. usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33

    We used its matched contact table, window powers, fixed score, source metadata, and pinned raw retrieval recipe. These inputs enabled the exact shaft count AUC benchmark and paired conditional tests. All parent files were verified and preserved. The new result uses the same cohort and score.

  2. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    The analysis reused verified features and source labels derived from OpenNeuro ds004100 version 1.1.3; the dataset metadata record this exact version and CC0 license.

  3. supportsdoi:10.1038/s41598-019-42347-y

    This study supplies the score direction used by the parent feature package; the present study uses a 0.5 to 1 Hz slow band and does not claim an exact replication.

  4. supportsdoi:10.1088/1741-2552%2Fac90ed

    This study motivates controlling for spatial sampling in intracranial EEG; its fitted spatial model and estimates differ from the fixed shaft count null used here.

Cited by

1 publication

Public catalog entries on Sciscape.