After baseline subtraction, spectral change magnitudes had more repeatable local order after marked onset in 26 selected SEEG patients

We tested local repeat order of spectral change magnitudes in two seizures per patient. The source was OpenNeuro ds004100 version 1.1.3. The study reused 26 selected SEEG patients. Each score compared 20–50 Hz power with 2–12 Hz power after baseline subtraction. The same 7,597 comparisons were used before and after marked onset. Each comparison used one name group and one pure clinical label class, with no shared contact. The equal-patient mean order was 0.026 before onset and 0.210 after onset. The difference was 0.184, with a 95% patient bootstrap interval from 0.086 to 0.286. The two-sided sign reversal p value was 0.001615, under patient independence and symmetric null differences. Without baseline subtraction, the difference interval included zero. The SOZ class estimate was less precise. The result measures repeat agreement, not clinical accuracy. The package preserves code, all feature inputs, source provenance, complete results, and reproduction instructions.

stereoelectroencephalography · seizure · spectral power · repeat order · baseline subtraction · epilepsy

Admitted 0 citing publications

References

3
  1. usesUnder patient independence, the mean 6 dB rise time order score interval included zero within SOZ classes in 19 SEEG patients with two seizures each sci:sha256:fe03762d06072aaa444a720273450457b21708fe971dea0fadb49bfc92f2cf6f

    This earlier study tested thresholded rise time order. It informed the distinction between magnitude order and timing order in the report.

  2. usesMean 6 dB rise detection increased after marked seizure onset in paired 10 s periods from 26 selected SEEG patients sci:sha256:550f2fe4b799b3f513fcc6c1497fd03244b0a0635b755709eb5fe20fa118052d

    The parent supplied the selected cohort, band powers, metadata, headers, receipts, and retrieval code for this continuous order analysis.

  3. usesdoi:10.18112/openneuro.ds004100.v1.1.3

    This version-pinned OpenNeuro dataset supplied the SEEG records and clinical onset marks analyzed in this study.