Shaft clustering inflated pair-level SOZ test positives in 87 patients across four SEEG cohorts
In 87 patients from four public SEEG cohorts, naive pair-level Mann–Whitney tests produced false positives for a mean of 19.6% of random shaft-clustered labels (95% bootstrap CI 17.2–22.1%; 82/87 patients exceeded 5%). A block null that moved whole SOZ runs among random shaft positions produced a 3.8% rate (95% CI 3.3–4.3%), slightly below the nominal 5%. For clinical SOZ labels, 46/87 patients showed a significant higher feature value under the naive test and 24/87 under the block null; 22 were significant only under the naive test, and none only under the block null (McNemar p = 2.4×10⁻⁷; Holm-adjusted p = 4.8×10⁻⁷). Median between-shaft feature variance share was 0.31, and its exploratory Spearman correlation with the naive false-positive rate was 0.42. The block null preserved SOZ run lengths but did not model electrode placement or relations between shafts. Analyses used short archived interictal clips and one feature per cohort; clinical SOZ labels are not ground truth.
stereo-EEG · SEEG · epilepsy · seizure onset zone · SOZ · false positive rate · Mann–Whitney test · block permutation · electrode shafts · interictal biomarkers
References
2- usesIn 117 SEEG patients, the top interictal HFA pair was in the clinical SOZ less often than its AUC predicted sci:sha256:6c85dc6f3540bdd41aaeb79a7fbecee27e8b50ac476c990e8241c271ddd4e414
Archived per-pair interictal feature tables, row rules and primary features of the 4 cohorts are the inputs.
- supportsIn 256 RAM patients, pair-level SEEG tests had 76–79% false positives under random labels; patient-level tests had 4.6–5.3% sci:sha256:702cad0cc9458f3cd5bfb4c9bb699326ade05ce17c4a2fb65b767d3b6877db64
Shows the same inflation of pair-as-independent tests inside single patients, in other cohorts and with shaft-structured labels.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.