Per-pair SEEG spectra repeat across RAM FR1 sessions, but relative theta power misses the planned stability threshold
We measured how well per-pair SEEG spectral features repeat between two recording sessions of the same patient. The analysis used 85 patients with ses-0 and ses-1 from OpenNeuro ds004789 (RAM FR1), version 3.1.0, and 7,353 bipolar pairs matched by label. For each session, we analyzed a 60 s segment from the first word event. Across pairs, median per-patient Spearman correlations were 0.80 for delta, 0.69 for theta, 0.81 for alpha, 0.82 for beta, 0.84 for gamma, 0.87 for aperiodic exponent, and 0.91 for total power. All seven features showed positive between-session agreement (Holm p = 0.0007). Six met the planned stability rule (median r >= 0.7); relative theta power did not. Between-session agreement was lower than agreement between 30 s halves of one session for all seven features (Holm p = 0.0007), while retaining approximately 84-93% of the within-session value. About one third of patients had r < 0.7 for most features. Exploratory analysis found that a pair's session-0 spectrum explained a median 83% (95% CI 75-87%) of within-patient across-pair variance in session-1 1-45 Hz log power. The comparison with position maps from other patients (8-12%) is approximate. The session gap is unknown; sessions are not confirmed to be on different days. Results concern the first 60 s of the same FR1 task state and do not directly apply to rest or sleep.
SEEG · spectral reliability · session-to-session · RAM FR1 · intracranial EEG · power spectrum · OpenNeuro
References
3- usesA cross-patient MNI map predicts about 10-16 % of the within-patient SEEG spectral variance of a bipolar pair, at a 5-10 mm scale sci:sha256:052e47beaab0a8d0a94c8c191c4e80623d7f1ba8e61ec8ea8212a4102b11a111
We compared its 8-12 % position-map value with the session-to-session ceiling measured here.
- usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32
We reused its spectral fetch code, 60 s segment rule, pair acceptance rule and subject table.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The analyzed SEEG recordings are from OpenNeuro ds004789 version 3.1.0 (RAM FR1).
Cited by
4 publicationsPublic catalog entries on Sciscape.
- usesSEEG neighbours shared session changes no more than 30 s noise in 64 RAM FR1 patients
Source of the archived two-session 30 s half spectra (ds004789 RAM FR1) that this analysis uses unchanged.
- usesIn 84 same-implant RAM FR1 patients, 60-second SEEG spectral changes did not track free-recall changes across sessions
Input spectra for both FR1 sessions (copied with SHA-256 values).
- usesMean SEEG spectra identified 54% of 84 patients across two sessions
Source of the archived two-session 60 s bipolar SEEG spectra (ds004789 FR1) used as input.
- supportsSEEG 4–13 Hz Peak Frequencies Were Moderately Stable Across Two RAM FR1 Sessions
Extends its band-power and exponent session reliability to the 4-13 Hz peak frequency and finds similar moderate-to-good stability.
- usesSEEG 4–13 Hz Peak Frequencies Were Moderately Stable Across Two RAM FR1 Sessions
Input spectra (60 s, two sessions, halves) and pair acceptance come from this package.