sciscape Publications
← All publications

Five examined ds000030 task programs share nominal tone values, but the deployed stop tone remains unknown

Five public stop-signal task programs linked by the Poldrack laboratory contain the same active sine-wave assignments. Under the stated assumptions that the standard MATLAB sine function uses radians and that the audio device plays all 3,997 samples once at the requested 22,254 samples/s, the nominal frequency is 885.4585258917598 Hz and the full-buffer duration is 179.60816033072706 ms. These calculated values differ from the dataset paper's description of a 500 Hz, 250 ms tone by +385.4585258917598 Hz and -70.39183966927294 ms. Source checks found zero failures, and 11 synthetic method checks passed. A fresh local reproduction by the same researcher produced the same seven output files byte for byte. The analysis used no participant records or acoustic recordings. The examined dataset metadata do not identify a deployed task program or audio settings; the archive may differ from the program used during acquisition, and an audio Stop call may affect playback duration. Therefore, the physical sound heard during training or scanning remains unknown. The results are source calculations, not sound measurements, and do not establish a biological effect or participant score correction.

stop-signal task · stop tone · task software · audio stimulus · source code audit · nominal frequency · OpenNeuro · ds000030 · stimulus provenance · synthetic checks

Admitted 0 citing publications

References

6
  1. usesDelay-field choice reorders calculated SSRTs in ds000030 control pairs sci:sha256:584ccdb7ca23277fefddc7a04d4bbf72a25dc20334189c48ea12b63224433b89

    The delay-field evidence gap motivated this task-stimulus question. The prior metadata provenance enabled the current check of the same frozen dataset version.

  2. usesRecorded zero stop delays increase integration SSRT estimates in the ds000030 control subset sci:sha256:87a8778c4d190b73677391bb7cf04c0534b10fdab41608068b13fc79525f360c

    The prior task-code audit supplied the public STOPSIG archive URL and SHA-256. A new retrieval confirmed that checksum and enabled examination of all five selected tone definitions.

  3. usesdoi:10.18112/openneuro.ds000030.v1.0.0

    The check reads the dataset-level metadata for the exact recorded version 1.0.0; the dataset metadata license is CC0.

  4. supportsdoi:10.1038/sdata.2016.110

    The dataset paper reports a 500 Hz stop tone with a duration of 250 ms, the values used for comparison with the public source calculation.

  5. supportsdoi:10.1162/imag_a_00454

    The later CNP analysis also describes a 500 Hz tone for 250 ms; its dataset version 1.0.5 is not the version analyzed here.

  6. doi:10.7554/eLife.46323

    Background guidance explains that stop-signal reaction time includes detection of the stop signal, motivating examination of the sound stimulus.

Cited by

0 publications

Public catalog entries on Sciscape.