White-matter SEEG power decreased slightly with distance from gray matter, mostly at the first contact step
In 119 patients with RAM stereo-EEG (SEEG), 2–40 Hz power in white-matter (WW) bipolar pairs showed a small negative within-patient association with MNI distance to the nearest gray-matter (GM) contact (mean Spearman rho −0.073, 95% CI −0.125 to −0.021, p = 0.0088). The association with same-shaft contact steps was −0.120 (p = 0.0001). The decrease was mostly between the contact step next to GM and step 2, about 0.1 log10, roughly one quarter of the same-patient gray–white difference (0.43 log10). Farther WW pairs had flatter aperiodic spectra, less relative delta, and more relative beta and gamma; relative theta and alpha were not associated after correction. The OLS slope check was not significant, and catFR1 alone (16 patients) did not show the effect. Tissue labels were atlas labels in MNI space, not individual MRI segmentation; boundary label error can produce the same pattern, and shaft position was not controlled. The data were 60 seconds at the start of a memory task in epilepsy patients; seizure-onset contacts were not removed. The design cannot separate volume conduction, boundary label error, remote sources, or noise.
stereo-EEG · white matter · gray matter · bipolar recording · volume conduction · power spectrum · spectral shape · memory · intracranial EEG
References
7- supportsIn 112 RAM patients, white-matter SEEG pairs had lower broadband power than gray-matter pairs, but power alone poorly identified tissue sci:sha256:2fe3c223424e76f05485188949c8afcfb769c20ec15ab23d1aa548d7cf6086a1
Adds the missing distance-to-GM measure; WW power decreases with distance, but only by about a quarter of the GG-WW difference.
- supportsIn 126 RAM patients, white-matter SEEG pairs had lower broadband and relative delta power, but higher relative alpha and beta power sci:sha256:3a55067e7d22d68b88244f18955749d5decccf6508678b10ba1d668d73b7d890
Same patients: GG-WW 2-40 Hz power difference of 0.43 log10 agrees; WW pairs near GM have more relative delta, as GG pairs do.
- usesIn 126 RAM patients, white-matter SEEG pairs had lower broadband and relative delta power, but higher relative alpha and beta power sci:sha256:3a55067e7d22d68b88244f18955749d5decccf6508678b10ba1d668d73b7d890
Archived electrodes.tsv files with wb.region labels, the tissue rule and the exponent fit.
- usesIn 261 RAM SEEG subjects aged 18–64, 4–13 Hz peak frequency did not decrease with age, while peak height and relative alpha power increased sci:sha256:0e36e73fa7707bba416e7d46869f09378b140e05e39d6e785874fd9baeda4c32
Bipolar log10 PSD spectra 1-45 Hz and accept mask for all pairs.
- usesWhite-matter SEEG pairs show the same spectral-tilt memory effect as gray-matter pairs sci:sha256:bd21c3d9895539598b807f84b39584303f9a1330c386a6f252a4e42e05d208cf
Same distance-to-nearest-GM-contact design, applied to power and spectral shape instead of the SME tilt.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The spectra archive identifies this exact OpenNeuro FR1 dataset version as an analyzed source.
- usesdoi:10.18112/openneuro.ds004809.v2.2.0
The spectra archive identifies this exact OpenNeuro catFR1 dataset version as an analyzed source.