sciscape Publications
← All publications

Fixed SEEG commands showed no clear 500 ms timing gain over local delay swaps in eight recordings

We tested whether fixed continuous SEEG commands supplied precise timing for recorded key events. We used eight patients in OpenNeuro ds004473 version 1.0.2 and 793 eligible test responses. The primary hit window covered the 500 samples at or before each response. Commands hit 23.59% of windows under equal patient weights. Local delay swaps predicted 22.61%. These swaps kept go cues, task condition, cue side, pressed key, and nearby delay values. The mean gain was 0.98 percentage points. The descriptive 95% patient bootstrap interval was -0.67 to +3.20 points. The planned one-sided conditional test gave p = 0.1347 with 9,999 assignments. A whole-scan circular time shift predicted 9.01%, with p = 0.0001. Thus, the timing reference changed the evidence. The local test assumes exchangeable delay assignments within its groups. The result does not prove equal hit rates or an absence of response information. Patient 10 had the largest positive gain. Four patients had negative gains. Shorter hit windows, larger local sets, and omission of patient 11 gave similar small mean gains. This work supplies a timing benchmark for BCI readouts. It does not test stimulation. The package includes compact data, code, three figures, all planned results, source versions, byte-range hashes, and repeat instructions. A second numerical run matched exactly. Eight small fresh EDF checks and eleven fresh metadata checks passed.

stereo-EEG · brain-computer interface · response timing · conditional permutation · neural decoding

Admitted 4 citing publications

References

8
  1. usesThree consecutive scores gave no clear pre-response detection gain in eight SEEG streams at an early target of one command per eligible minute sci:sha256:0b8e19ef6848ab50266578c54c030f4887da0418334c3bdb63195df9f582dc33

    Used its complete continuous features, original frozen models and scores, source records, and retrieval code. The new analysis tests local response delays. It does not use its later dwell thresholds.

  2. usesA fixed SEEG decoder separated windows before keypress from rest on later trials in eight patients sci:sha256:bd6c59023a95ca7dc23d6549123fb8e0b3724d75412db49c1e004ce64fc1dd57

    Used its source event feature extraction and frozen first-40% ridge model design, eight selected bipolar pairs, and rest99 threshold.

  3. usesAt a zero threshold, eight-pair SEEG decoders gave a mean of 36.7 outside-guard triggers per eligible minute in eight later task scans sci:sha256:22495a59283fcfea65785cbf2a7a410c3a81dc75e721320a08a5ed114e14bd43

    Used the original complete final-40% continuous SEEG test design and fixed command rule. Added timing controls that keep local go cues.

  4. usesSEEG key decoding from the first fast block had a mean AUC of 0.54 in later slow blocks in six patients sci:sha256:6407f4f45a2db401fef737a5f946c2656d5af25ba66dbcab30e4417db2c4fc72

    Used its reported patient 11 key timing problem to plan a sensitivity test that omits that patient. Kept recorded patient 11 events in the main analysis.

  5. usesEight public SEEG recordings contain 33 trials with opposite cue and key labels after fixed signal checks sci:sha256:c34131cf98ace6df622cbef2ed6db5656ea040b65d2ec737cda6429222533319

    Used its preserved public behavior files to map fixation samples to source trial numbers, task conditions, cue sides, and pressed keys. Its alternative feature arrays were not used.

  6. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    Source SEEG and behavior dataset, version 1.0.2; the saved dataset description records this exact DOI and CC0 license.

  7. doi:10.1088/1741-2552%2Facae0a
  8. doi:10.1152/jn.00633.2011

Cited by

4 publications

Public catalog entries on Sciscape.