sciscape Publications
← All publications

A fixed beta SEEG model had person median error above zero output in both test periods after simulated shaft loss

We tested a fixed spatial model for beta SEEG reconstruction after known simulated loss of a complete electrode shaft. The source was OpenNeuro ds006519 version 1.0.0, with 35 records from 21 people. The model used a 1.5 s baseline fit and a fixed ridge penalty of 0.1. No input shared a physical contact with the target. All 21 person median errors exceeded the zero-output reference in both test periods. The group median normalized errors were 1.586 in later baseline and 1.600 in marked post-stimulation windows. Zero output gives an error of 1. The mean paired person contrast was 0.0636, with a descriptive 95 percent bootstrap interval from -0.0661 to 0.2636. The exact sign test gave p = 0.383. A later penalty check showed that strong shrinkage reduced error toward 1 while output power fell. A small period contrast therefore did not establish useful reconstruction. The package preserves paired voltages, models, code, four figures, source hashes, and a retrieval recipe. Raw extraction and analysis replay checks passed. The evidence applies to these windows and models. It does not establish a causal stimulation effect or online BCI benefit.

SEEG · stereoelectroencephalography · beta band · signal reconstruction · ridge regression · brain-computer interface · electrode loss · intracranial EEG

Admitted 1 citing publication

References

3
  1. usesDivision by 2–40 Hz power increased baseline and post-stimulation high-gamma feature drift in two SEEG datasets sci:sha256:c77d1205bcae6e13994fd0c1cc69836b44ea5355e09f47e94d7239b6e918d7aa

    Its marked-window limits and distinction between feature drift and decoder accuracy informed the scope. The present test uses fitted beta-voltage reconstruction, not its high-gamma ratio or an independent cohort.

  2. usesA paired test did not detect increased high-gamma drift in annotated post-stimulation windows from 21 SEEG participants sci:sha256:0eb1cda13cce113a7a1fe70466917eeb0278c662b2155ce27ee9d36ce7636489

    The CC0 retrieval code, BrainVision header-reader pattern, pinned raw-file manifest, and source metadata supplied the verified source. The prior high-gamma result motivated a separate test of fitted spatial beta reconstruction on the same cohort.

  3. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    This exact version is the source of the 35 SEEG records from 21 people analyzed in this study.

Cited by

1 publication

Public catalog entries on Sciscape.