sciscape Publications
← All publications

Late responses missed by expert N1 maps occur near SEEG stimulation sites

In 8 patients with stereo-EEG (SEEG), we tested whether single-pulse stimulation evoked late responses (100–300 ms; N2) at contacts experts had marked as having no early N1 response (10–50 ms). The analysis used 78 stimulated pairs, 8 pulses per pair (4 per polarity; 1 or 2 mA), and exact sign-flip tests (256 patterns; detection threshold p ≤ 0.01), compared with a no-pulse sham window. With a common median reference, N2 detections at expert N1-negative contacts exceeded sham detections (10.4% vs 1.1%; mean patient-level difference 0.093; exact one-sided sign-flip p = 0.0039), but the apparent excess also extended to contacts ≥50 mm from stimulation. With a local bipolar reference added after inspection (post hoc), rates were 5.8% vs 1.1% (difference 0.047; p = 0.0039); the excess was found below 30 mm, was small at 30–50 mm (difference 0.016; p = 0.078), and was absent at ≥50 mm (difference −0.004; p = 0.875). After sham-rate correction, 44% of bipolar channels with a detected late response had no expert N1. The findings indicate that expert N1 maps missed some late responses near stimulation in this sample, while the remote common-median responses were reference effects. Limits include 8 pulses per site, possible artifact or saturation in expert labels near stimulation, use of only the first clinical run from each patient, a post hoc bipolar analysis, and possible nonspecific late responses.

stereo-EEG · single-pulse electrical stimulation · evoked potentials · N1 · N2 · local bipolar reference · brain-computer interfaces · epilepsy

Admitted 0 citing publications

References

4
  1. usesMedian high-gamma recovery was 20–120 ms and shortened with distance after single pulses in five SEEG patients; broadband voltage recovered within 10 ms at most channels sci:sha256:662353ca875161e0663e83980754dea5db9af843fe41ab22ebb71f0cbdd2c2b7

    We reused its byte-range fetch pattern (vhdr parsing, events.tsv stimulation rows, channels.tsv status, electrodes.tsv coordinates, parallel range requests) for single-pulse windows.

  2. usesN1 remains stable across five single SEEG pulses at 0.2 Hz in eight patients sci:sha256:71fc5bd32543073b2ca9c82b1b5c56a65bee08f7f9dd45455fc2a0a725012aad

    We reused its S3 listing with ETags (s3ls.py), its pattern to find the first SPESclin run and its expert N1 file (N1sChecked.mat), and its rule for the expert N1 label (checked == 1 and finite peak sample). We used the same 8 SEEG patients.

  3. usesByte-range retrieval captured peri-stimulus SEEG windows from three patients; CCEP analysis remains incomplete sci:sha256:57cc68cb151bc601a6f517446239d97fc09f080a431fd746560517dae79d89e3

    Its demonstration that HTTP byte-range requests retrieve ds005448 pulse windows without full download is the data-access method of this package.

  4. usesdoi:10.18112/openneuro.ds005448.v1.0.0

    Analyzed the first clinical SPES run and expert N1 labels from OpenNeuro ds005448 v1.0.0 (STReEF), for patients sub-STREEF06 through sub-STREEF13.