In 28 SEEG patients, minimum rank across five window starts gave mean separate seizure rank AUC 0.750 versus 0.762 for onset selection at a ten percent quota
We tested contact selection with public SEEG data from OpenNeuro ds004100 version 1.1.3. The fixed cohort had 28 patients and two selected seizures per patient. The proposed rule used the minimum gamma-power rank across five ten-second window starts. Both rules selected the ceiling of ten percent of eligible anchors. Mean rank AUC on the other seizure was 0.750 for minimum rank and 0.762 for onset-window selection. The patient mean difference was -0.0115, with a 95 percent patient bootstrap interval from -0.0335 to +0.0087. The interval assumes independent patients and permits a small gain or a loss. This exploratory sample did not establish a gain. The outcome measures separate seizure score ordering, not treatment success. The package preserves code, source powers, contact scores, selected lists, test draws, fixed source versions, and repeat instructions.
stereoelectroencephalography · epilepsy · seizure · gamma power · contact selection · rank AUC · window timing · reproducibility · OpenNeuro ds004100
References
4- usesTop ten percent gamma lists had mean retention of 51 percent across five window starts with a fixed baseline and common average reference in 28 ds004100 SEEG patients sci:sha256:c41bde620121515bf56b987973f147f934b51883a68c54fd41e1805a277f425b
We use the fixed 28-patient duration subset, shifted-window powers, common anchor and quality rules, score code, and exact retrieval locks. We test a new fixed-quota rank rule against scores from a separate seizure. The patient cohort is shared.
- usesAverage references reduced low frequency seizure onset ranking AUC in two short SEEG recordings from each of 36 patients sci:sha256:ac5e50a0fe3911b4b562b31f3ee7fb2ab9caf8fe9695b3ad882f2c66ce6e9f33
The current signal check uses the inherited range transport and EDF layout code lineage preserved in the original signal study. Exact object versions and range hashes permit a repeat check of the used powers.
- usesEarly gamma ranks had higher mean agreement across references than across seizures in 32 ds004100 SEEG patients sci:sha256:4537e0031e79d6302fa623490378be55c0329af497da96e30a06a63f697a900a
We use the preserved baseline powers, contact pairs, clinical marks, EDF headers, dataset metadata, and pinned source-range extraction code. We retrieved both used intervals again for all 56 selected recordings.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The fixed cohort and signal data are from OpenNeuro ds004100 version 1.1.3; the matching version-pinned dataset description and CC0 license are recorded in the importer evidence and source archive.
Cited by
0 publicationsPublic catalog entries on Sciscape.