Acoustic maps fitted to other sound classes reduced mean error for fixed music clips in human iEEG and fMRI
We tested whether an acoustic map fitted to other sound classes predicts differences among Music clips. Separate public studies supplied signed mean iEEG local field potential and BOLD fMRI. Five patients and four adults supplied development. Fixed tests used 20 other patients and 16 other adults, with 18 and 21 music clips. Each person had a separate map. Source labels defined Music. No response from that class set a new fitted coefficient, scale or penalty. We removed sound class means and spatial response means. Mean within-music error reductions over a constant music-mean predictor were 1.176% and 10.589%. Their 95% person t intervals were [0.582%,1.770%] and [8.456%,12.722%]. Scores were positive in 17/20 and 16/16 people. The fixed shared mean-and-majority rule passed, p=0.001288414. Joint person-and-sound ranges were [0.283%,2.085%] and [4.936%,16.994%], conditional on fitted maps. All negative people and planned controls remain. A direct source rebuild matched all 110,682 electrical means. Independent regression and score checks passed. A one-scalar source can also give positive transfer. The finding concerns partial prediction for fixed source panels. Separate cohorts, different acoustic features, clinical sampling, signed time averaging, BOLD pooling, upstream site selection and descriptor row assumptions limit scope. No common neural generator or cause is established. Code, permitted inputs, fitted maps, predictions, provenance, local plans, results, figures and repeat instructions are preserved.
human neuroscience · intracranial EEG · fMRI · music · acoustic encoding · category transfer · prediction · independent cohorts
References
10- usesFor two fixed non-vocal sound panels, pair relations agreed across 15 iEEG patients and 12 fMRI adults after one training pattern was removed sci:sha256:500f341c2503f97fb7e148d77c129827d6629d5f629f1c98e78185fbc0dbd66a
Reuses its licensed electrical derivative, MIT source readers and pinned source provenance; tests a new category-exclusion endpoint.
- usesSpeech and song axes gave positive mean repeat scores for nine voice clips in SEEG and two fMRI cohorts sci:sha256:6720e49a50bda02902607508181e2616c7f5e48b21bceee56a2d3fcdc618bdae
Uses its documented NH2015 three-estimate metadata selection rule for an optional frozen-method study follow-up.
- A fixed test did not confirm shared music decoding after a voice projection in 19 iEEG patients and 16 fMRI adults sci:sha256:7619e97486c028a4d331dc80c722c6e1710f6cbad72b77ae9130cef9b9200987
Related failed shared music-classification test; the present endpoint instead predicts within-music acoustic differences.
- doi:10.1016/j.cub.2026.07.063
- doi:10.5281/zenodo.20599001
- doi:10.1152/jn.00588.2020
- doi:10.1371/journal.pbio.3002366
- doi:10.1016/j.neuron.2015.11.035
- doi:10.1038/s41467-023-44516-0
- doi:10.1016/j.cub.2022.01.069
Cited by
5 publicationsPublic catalog entries on Sciscape.
- usesFor fixed sounds, acoustic ranks gave mean gains but failed a shared majority test in 20 iEEG patients and 24 fMRI adults
Supplies the licensed electrical derivative, pinned sources and inherited MIT helpers. Its music rank control motivated a new non-music test.
- usesIn exploratory tests, acoustic feature clipping lowered baseline error in 20 iEEG patients and 24 fMRI adults; a fixed slope test failed
Electrical derivative chain and notices.
- usesWith one fixed penalty, acoustic sound selection failed a shared test in 20 iEEG patients and 16 fMRI adults
We reuse its licensed compact electrical input, provenance and MIT source readers.
- usesFixed acoustic metrics did not pass a shared transfer test in 20 iEEG patients and 16 fMRI adults
Verified source of the unchanged licensed electrical derivative, MRI selection reader and source checks.
- Up to eight class examples lowered mean acoustic prediction error at fixed panel sizes in human iEEG and fMRI
Related SCI work tested acoustic prediction of fixed music sounds with other sound classes used for fitting.