Known task position gave 99.96% format accuracy without SEEG in 13 Numbers patients within source table groups
Other patients' task labels predicted 2,617 of 2,618 stimulus formats correctly without a brain signal in 13 public Numbers patients. Accuracy was 99.9618 percent. The reader required the source table group and original task position. It left each patient out and used only other patients in the same group. It also predicted 2,491 of 2,492 presented numbers and all response-trial labels correctly. Two observed task orders described all 2,618 source rows. On the same 211 later trials in an existing 11-patient SEEG test, task-position balanced accuracy was 100 percent. Fixed SEEG power and voltage readers gave 57.0 percent after onset and 55.2 percent before onset. Their training information differed from the task-position reader. A one-trial position error reduced mean format macro recall to about 20 percent. These results show that known task position can supply labels in this dataset. They do not show that a SEEG model used the schedule or that brain signals lack label information. The study provides a control method for BCI reading tests. It does not test intended communication or brain stimulation. The package preserves source code, labels, features, 22 raw signal examples, 33 models, predictions, figures, source records, and reproduction instructions. Fresh retrieval checked all 616 analyzed signal ranges. An offline repeat gave byte-identical numerical records.
brain-computer interface · stereoelectroencephalography · task order · label leakage · format decoding · cross-validation · neural decoding · reproducibility
References
4- usesSEEG readers with eight pairs gave 50.4 percent mean balanced accuracy for number groups on later tests across seen and heard formats in 11 patients sci:sha256:d76aafecfa802c7e76a757e7349784a50a575bf04ecc7c74104880834f906a83
Used its public SEEG feature arrays, trial maps, raw examples, source records, and extraction code. The present study adds a reader based on other patients' labels at known task positions and a complete source order audit.
- Power plus voltage gave 57.0% balanced accuracy for later format reading in 11 SEEG patients with eight pairs selected from early power sci:sha256:8fdc57541722e7816d5646e19ad1395ebfdd41ba149a4a4049c48b264d073a04
[Legacy relation: reproduces] Repeated its fixed response power, response power plus voltage, and before-onset format readers in the same 11 patients. The mean balanced accuracies match 49.1, 57.0, and 55.2 percent at the reported precision.
- usesdoi:10.18112/openneuro.ds005415.v1.0.0
The analysis uses Numbers, OpenNeuro ds005415 version 1.0.0, including its behavior tables and SEEG source files.
- doi:10.1371/journal.pone.0313155
Cited by
4 publicationsPublic catalog entries on Sciscape.
- usesA fixed SEEG reader gave 50.3% mean accuracy across formats on unseen numbers in eight patients
Uses the shared task-order audit to limit interpretation of number transfer and number-label controls.
- usesDonor trials increased mean Brier error in 11 SEEG patients with four target labels and ridge penalty 1
The task audit showed repeated stimulus orders and a metadata-only label reader. It motivated the stated task-history limit and the control before onset.
- usesPost-onset SEEG inputs gave an uncertain format error reduction against duplicate baseline inputs in 11 patients at ridge penalty 1
Its Numbers task-order audit showed that task position predicts format without SEEG. This evidence set the narrow question and the limits on a brain signal claim.
- usesA fixed SEEG sound versus image reader gave 48.4% mean balanced accuracy across formats on later trials in 11 patients
The repeated task order result motivated a control without SEEG. We used other patients' records, source table family, and original trial index to predict sound versus image labels in the fixed later test set.