sciscape Publications
← All publications

Adding band correlations increased mean later log loss for rest and pre-response states in eight SEEG recordings

We tested whether band correlations add useful information to SEEG band power. We used rest and pre-response windows from eight public recordings in OpenNeuro ds004473 version 1.0.2. Each reader learned from early trials and predicted later trials. The electrode pairs were fixed by an earlier power study. Penalties were chosen within the early period. Mean later log loss was 0.53489 with power alone and 0.56591 with added real band correlations between different electrode shafts. Six of eight recordings had higher loss with the added features. The paired loss reduction was -0.03102. Its descriptive 95% person bootstrap interval was [-0.06609, +0.00008]. The exact two-sided sign-flip p value was 0.140625. Thus, the tested reader did not show a mean gain. The interval includes zero change. Fixed controls tested imaginary components, correlation alone, phase shuffles, and a fixed penalty. The package includes exact voltage buffers, source range records, all predictions, two figures, and code. Independent checks and a full numerical replay passed. This exploratory result applies to these selected pairs and event windows. It does not test continuous control or brain stimulation.

stereoelectroencephalography · SEEG · band power · band correlation · cross spectrum · logistic regression · brain-computer interface

Admitted 0 citing publications

References

5
  1. usesFiltering before fourfold sample removal gave 70.6% mean balanced accuracy in later trials from eight SEEG recordings sci:sha256:8bc11c5e9496aba0a89fbf8535edb5ce1336d5a00cc9df2b9795ddfb7b8ddde4

    This publication supplied the exact selected voltage buffers, source metadata, and numerical helpers. We checked 109 input files against its hashes. The buffers enabled a new comparison of band correlations with individual power.

  2. usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd

    This study supplied the original early power choices, retained trials, and EDF range helpers. We kept its eight pairs per person and all retained trials. These fixed choices define the tested scope.

  3. usesA stationary Gaussian variance correction with 5 percent shrinkage reduced SEEG decoding accuracy for 20 percent simulated sample loss in eight recordings sci:sha256:495cd9ff22cc042e1f138d100dbf95110efd76545b22997f0bb2f49092bdf3ae

    This earlier voltage package supplied the selected input buffers through the immediate source. Its archived records preserve the voltage retrieval lineage.

  4. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    The analysis uses the eight recordings in OpenNeuro ds004473 version 1.0.2.

  5. doi:10.1088/1741-2552%2Facae0a

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.