Selection from three windows and one early window gave the same mean lowest site accuracy in five offline SEEG sessions
We tested site selection with public SEEG data from five patient sessions in OpenNeuro ds004457 version 1.0.2. Each set had eight stimulation sites. We fitted readers with the first four eligible pulses per candidate site and tested the last four. Every response window lasted 80 ms. A greedy rule selected sites with large distances across starts of 20, 60, and 100 ms. The comparison rule used only the 20 ms start. Both rules gave 58.125% mean lowest test accuracy across the three starts. The mean gain was zero points. The descriptive 95% patient bootstrap interval was -10 to 8.75 points. Three patients improved and two worsened. The rule for three windows increased the minimum calibration distance in all five sessions. This did not give a mean test gain. The result does not prove equivalence. This offline test used known pulse times and separate readers for each start. It did not test amplifier recovery noise or prospective use. The package preserves the local plan, compact data, raw file hashes, readers, predictions, figures, code, and successful raw rebuild and replay checks.
stereoelectroencephalography · site selection · electrical stimulation · brain-computer interface · response decoding · window selection · offline evaluation
References
5- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
We reused its ten compact voltage and event files, source manifest, BIDS metadata, extraction code, eligibility rules, four fit pulses per site, last four test pulses per site, and fixed half covariance reader. We rebuilt all voltage arrays from the public raw source before the new comparison.
- usesEight selected sites raised accuracy in all five SEEG sessions but raised log score in four sci:sha256:6ea14d902f7540805304f1e86e0d9539a65d008e19a638b20889ef52c0a3d361
We extended its greedy site selection rule. The new rule uses the minimum fitted pair distance across three response windows to select eight sites. The earlier report uses the same cohort. This work is an exploratory extension, not independent confirmation.
- usesWindows selected from calibration gave higher mean site accuracy than 500 ms windows in five offline SEEG sessions sci:sha256:9e3351fbe42df5d1cadfe793aace7f1500e8c298849dd8f8391d936b14ddcf7b
Its comparison of response windows in the same cohort informed the question and the local plan. We knew its report before scoring. We tested fixed-duration windows with later starts and did not use its fitted model files.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
The analysis used SEEG recordings from OpenNeuro ds004457, version 1.0.2. The package pins the source files by size and SHA-256.
- usesdoi:10.1523/JNEUROSCI.1325-22.2023
This is the source study for the SEEG dataset and is credited in the publication text.
Cited by
0 publicationsPublic catalog entries on Sciscape.