Source interval checks accepted theta features from one-second windows with saved zeros in 250 selected SEEG records
We tested a fixed theta power feature in 250 selected SEEG records from seven people in OpenNeuro ds007095 version 1.0.0. Each feature used a one-second window. Feature ends were tested every 5 ms from zero to two seconds after the last marked stimulation interval. The source interval check accepted inputs that still contained saved zero runs. These inputs made up 17.70% of accepted windows, with equal person weight. A controlled test replaced samples in earlier SEEG with native zero codes. For each channel and record, we took the median error in affected windows. We then averaged channels, records, and people. The mean was 9.73%. A fixed threshold changed decisions in 0.93% of event-accepted windows. A mask that also rejected complete zero runs accepted fewer windows. Its accepted values were unchanged in the controlled test. A proof for a fixed squared norm shows when a flagged sample cannot affect the feature. The package preserves complete inputs, pinned sources, code, traces, three figures, and independent verification. All 12 numerical result files matched a clean repeat. The test does not establish a neural recovery time or decoder accuracy.
stereoelectroencephalography · SEEG · signal processing · theta power · feature validity · stimulation artifact · brain-computer interface
References
3- usesZero sample runs continued after all 932 marked stimulation intervals in 250 selected hippocampal SEEG records sci:sha256:08b79fb28c0ad8ae5ce5f97718a82ab9495d0a888ebc9474e04e519df67d70f3
We used its fixed 250-record selection, complete native SEEG files, pinned metadata, and reader code. Its zero-run evidence set the source gap lengths. We added feature validity counts, a controlled power test, and a finite feature mask.
- usesdoi:10.18112/openneuro.ds007095.v1.0.0
The analyzed native SEEG files came from OpenNeuro ds007095 version 1.0.0; its recorded dataset metadata identifies the exact version and CC0 license.
- supportsdoi:10.3389/fnins.2026.1815732
This source paper supplies context for the selected responsive-stimulation records and the reported recommendation to begin post-stimulation analysis at least five seconds after stimulation onset.
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesTwenty-second calibration in the current record gave no clear theta power gain over calibration from the previous session in seven people with depth SEEG
Its finding that input validity must cover every sample used by a feature informed our checks of the complete calibration and test intervals. We computed new spectra and results; we did not reuse its feature scores.