Eight SEEG tests did not establish 50 percent precision under binomial bounds that assume independent trials, stable class distributions, and a 1 percent task rate
We tested whether a reader with no calibration false calls can establish at least 50 percent precision at an assumed 1 percent task-window rate. We used 2,014 retained trials from eight public SEEG records in OpenNeuro ds004473 version 1.0.2. Separate time blocks fitted the model, set the threshold, and tested the calls. A threshold at the largest calibration rest score reduced mean test false-call rate from 28.53 to 0.93 percent. It also reduced mean task detection from 69.49 to 14.13 percent. At the assumed task rate, precision for an equal-person class mixture was 13.25 percent. No record reached a 50 percent lower precision bound. Under the stated exact binomial rule, even perfect observed test decisions need 368 independent windows per class to pass that goal. Actual tests had 32 to 75 per class. The bounds assume independent trials and stable class distributions. This is an exploratory study in a reused clinical cohort. Its response-aligned windows do not label command intent. The package includes three figures, unchanged source features, new models and predictions, source versions and hashes, a sample-size calculator, and reproduction code. A fresh check rebuilt 240 windows from 48 source trials with no feature difference.
stereoelectroencephalography · brain-computer interface · precision · false-call rate · calibration · binomial bounds · sample size
References
6- usesCorrection with unlabeled rate estimates gave higher Brier error than known rate correction in eight SEEG tests at a simulated 10 percent task rate sci:sha256:b892355893f9c4a4eee2f1099be29fa09a3490dedfcb88a9ef534fd8d2ffe451
Its probability analysis at an assumed 10 percent task rate provided context for a reader with a low task rate. It motivated the new test of separate threshold calibration and finite-sample precision bounds at an assumed 1 percent task rate.
- usesEight SEEG pairs classify pre-response and rest windows at 70.7% mean balanced accuracy in later trials from eight recordings sci:sha256:c74068384c7c056974c8568aab987cf5a8eee9979a622c22efa1b67a911e77fd
We used all retained feature arrays, trial records, source metadata, raw range recipes, and extraction code from this publication. We fitted new models in separate time blocks and added threshold calibration and exact precision bounds.
- usesdoi:10.18112/openneuro.ds004473.v1.0.2
This versioned OpenNeuro dataset supplied the SEEG records and behavior used in the analysis.
- supportsdoi:10.1088/1741-2552%2Facae0a
The cited source study describes movement-related oscillations in this clinical SEEG task.
- doi:10.1093/biomet%2F26.4.404
- doi:10.1126/sciadv.aao1659
Cited by
1 publicationPublic catalog entries on Sciscape.
- supersedesEight SEEG tests did not establish 50 percent precision under binomial bounds that assume independent trials, stable class distributions, and a 1 percent task rate
This version corrects the package hash check. The check now ignores the separate metadata folder added by sci fetch. The analysis data, models, numerical results, and figures are the same.