Four pre-pulse coefficients increased mean relative SEEG prediction error in five patients at 50–250 ms with ridge penalty ratio one
We tested signed voltage detail before stimulation. The task was centered SEEG shape prediction beyond local amplitude and an early site mean. OpenNeuro ds004457 version 1.0.2 supplied five epilepsy patients. The ridge model used four signed cosine coefficients. Its penalty ratio was one. Slopes came from other sites in each patient. Five early pulses calibrated each site. Five later pulses supplied 50 to 250 ms test windows. There were 1080 scored links. Mean relative after-pulse error increased 0.797 percent. Mean relative before-pulse error increased 0.362 percent. The paired gain difference was -0.436 percentage points. Descriptive patient resample limits were -1.457 to 0.189 points. The conditional patient sign-flip probability was 0.6875. All seven planned checks had negative paired differences and ranges that included zero. Mean physical after-pulse error fell slightly. This change has different weighting from mean relative gain. The test did not establish a stimulation-specific prediction benefit. It did not establish absence of useful state information. All 120 raw files passed pinned source checks. A raw rebuild and analysis repeat reproduced all saved arrays and tables. Independent least squares checked 4320 primary fits. A second NumPy build reproduced all numeric results within a fixed tolerance. The package preserves code, matched input windows, all scores, primary fits, predictions, source hashes, and repeat instructions. This is an offline within-patient test with local site calibration. It does not test new patients or causal connectivity.
stereoelectroencephalography · electrical stimulation · voltage prediction · ridge regression · matched control · prediction error
References
7- usesA fixed voltage RMS model gave a mean late SEEG prediction gain of 0.08% on separate pulse halves in five patients sci:sha256:de3ec527b24eefabc4b3bb071f60b7c3d5dd210e52db7ded286a255e4bcb29d8
We used this pooled RMS voltage result as context for an amplitude comparator. It used the same clinical cohort. The present study tests signed detail, other-site slopes, and matched before-pulse windows.
- usesLocal amplitude increased SEEG prediction error in fixed ridge models with ten pulses per site in five patients sci:sha256:90ca56b8a16b4c5aa8d53cd988ab288b768c0a93af72bec8cfbba1edff975ee6
We used the local amplitude forecast result to define the new incremental signed-feature question. We read that result before the local plan. We did not reuse its fitted slopes or test scores. The present outcome is centered voltage shape.
- usesAn 80 percent band gave 82.1 percent mean coverage of test SEEG pulse waveforms in five patients at 50 to 250 ms sci:sha256:f03a52ff2f336fee5e8aedaec89ad7cd6e6db27800ca9e016d3115697a788aca
This archive supplied metadata, fixed receiver selection, source locks, and retrieval code. Its saved main windows enabled an exact input check. We retrieved native channels independently and added matched before-pulse windows. We did not reuse its uncertainty bands or scores.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Source data: the analysis used OpenNeuro ds004457 version 1.0.2.
- usesdoi:10.1523/JNEUROSCI.1325-22.2023
Describes the source recordings used in this secondary analysis.
- doi:10.1111/epi.17528
- doi:10.1038/s42003-021-02240-9
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.