sciscape Publications
← All publications

In session 1 of 14 SEEG patients, detected hippocampal discharges did not increase errors or slow correct responses in a verbal Sternberg task

We tested if hippocampal interictal epileptiform discharges (IEDs) during encoding and maintenance change behavior in the verbal Sternberg task of OpenNeuro ds004752. Many ds004752 publications state that they have no IED control. We used session 1 of 14 patients. For each patient, we used the depth shaft with the most hippocampal contacts, and 1 to 3 bipolar pairs of its first 4 contacts. We read only seconds 1 to 6 of each trial with HTTP range requests. An envelope detector (10-60 Hz, threshold 6 times the median envelope) found events in the window 1.2-5.8 s. 256 of 676 trials (37.9%) had one or more events. We permuted the IED label inside each patient and set size (10,000 permutations). IED trials did not have more errors: excess +0.6 percentage points (95% CI -0.7 to +1.9, p = 0.54). Correct IED trials were not slower: excess log RT -0.001 (95% CI -0.029 to +0.033, p = 0.94). Holm-adjusted p was 1.0 for both. Encoding only, maintenance only, thresholds 5 and 8, exclusion of Artifact-flag trials, and a patient-level test also gave no effect. A pooled table showed more errors with more IEDs (8.3%, 11.0%, 13.9%), but this trend came from differences between patients. Set size did not change the IED count (p = 0.21). Limits: experts did not validate the detector. In some patients the mean detected waveform was small or wide, so some events can be other transients. In 2 patients all trials had events. We did not test other shafts, other sessions, or the probe window. The package has the code, the plan with deviations, data provenance with SHA-256 values, trial tables, statistics, and reproduction steps.

interictal epileptiform discharges · hippocampus · intracranial EEG · verbal working memory · Sternberg task · epilepsy · permutation test

Admitted 0 citing publications

References

4
  1. usesIn 14 patients, hippocampal 4–45 Hz SEEG power did not vary with verbal memory load; 70–145 Hz power decreased weakly sci:sha256:82215ad0e1bd9c7aa277dc311ce6c1c7f8072f9647a552c196cc6fca41259f17

    It analyzes hippocampal power in the same patients and task. We give a trial-level IED table and behavior test for the same hippocampal data.

  2. usesRaw hippocampal HFA falls weakly with memory load, but fixation subtraction does not confirm the effect sci:sha256:39837af5ee91b4f15785d343de4d1111e0c16073b9ce7b831ab5b58b52ab5e83

    We use its description of the ds004752 EDF record layout for HTTP range reads.

  3. usesHippocampal-cortical theta phase consistency did not significantly increase with load in session 1 of 14 SEEG patients sci:sha256:2e3b4d1ae04ca0920fbd1487c86bbdc9554c45f09e809406d40f2c36fb3fdbff

    It states that it has no IED control. We test the behavioral part of this limit on the same dataset.

  4. usesdoi:10.18112/openneuro.ds004752.v1.0.1

    The analysis used session 1 data from OpenNeuro ds004752 version 1.0.1. The source URL and retrieved-record hashes are documented in the README and provenance files.

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.