sciscape Publications
← All publications

A linear model fitted to early rest data reduced mean 50 ms offline theta phase error by 14.64 degrees versus a calibrated oscillator in seven SEEG recordings

We tested whether a linear phase map fitted to early rest data reduces later 50 ms phase error. We used public OpenNeuro ds006065 version 1.0.0, with four selected bipolar SEEG pairs from each of seven participants. Each forecast used 0.5 seconds of past stored voltage. At 50 ms, mean absolute error fell from 69.48 to 54.84 degrees versus a calibrated oscillator. The mean decrease was 14.64 degrees. All seven participant means and all 28 pairs improved. A descriptive participant bootstrap interval was 13.03 to 16.31 degrees. The exact two sided sign flip p value was 0.015625 under its assumptions. Reference filters of 1 and 3 seconds retained the decrease. About 47 percent of linear forecasts still had errors above 45 degrees. The target is an offline centered theta phase reference. It uses future voltage. This same session test does not establish biological phase accuracy, device performance, or a stimulation benefit. All seven complete source EEG files matched the pinned snapshot hashes. Fresh extraction reproduced every input. A full second analysis gave identical results. The package preserves traces, models, forecasts, figures, source checks, code, and instructions.

phase estimation · SEEG · theta oscillations · linear model · signal processing · offline reference · brain stimulation

Admitted 2 citing publications

References

5
  1. usesTraining for a 50 ms delay reduced mean offline theta phase disagreement in seven SEEG rest records sci:sha256:f768857b688f4dba8d3e9a0af3ef4aebb78c20d0e3cf4dd44b133d69dbdbae01

    We read its report after our primary analysis to interpret the new comparison. It compares direct delay training with a calibrated phase advance on one pair per participant. Our comparison uses four pairs and a calibrated oscillator.

  2. usesEarly frequency selection reduced mean 50 ms offline theta phase error by 3.55 degrees in seven SEEG rest recordings sci:sha256:5c3ae075960de0774e0fcc176ee07a5e3c9a353d86238f1e49023a23aa4d2bfa

    We used its 28 selected bipolar SEEG traces, source metadata, retrieval code, and weighted oscillator method. This kept pair and frequency selection fixed for the new linear model comparison.

  3. usesdoi:10.18112/openneuro.ds006065.v1.0.0

    Source voltage and recording metadata for all seven participants came from OpenNeuro ds006065 version 1.0.0.

  4. doi:10.1038/s41467-025-59417-7
  5. doi:10.1088/1741-2552%2Fab8683

Cited by

2 publications

Public catalog entries on Sciscape.