Five time templates reduced SEEG site log loss with simulated grid errors up to 10 ms in five patients
We tested stimulation site reading with five possible pulse times in public SEEG data. The test used five patients and 183 sites from OpenNeuro ds004457 version 1.0.2. Artificial time errors moved the analysis window on a 5 ms bin grid. The five errors ranged from -10 to 10 ms with equal weight. Three pulses per site fitted templates and covariance. A fourth pulse fitted each reader's probability scale. Four later pulses per site tested the readers. For 732 physical test pulses, mean site log loss fell from 3.987 to 3.408 bits with likelihood averaging. Accuracy rose from 24.2% to 32.0%. Loss fell in all five patients. The exact two-sided patient test gave p = 0.0625. The maximum-score reader had 3.382 bits of loss and 32.5% accuracy. Averaging had no clear advantage over the maximum. The benefit persisted with a later window start. Pre-pulse results left possible background information. Fit and test times interleaved across sites. The evidence is limited to these offline sessions and artificial grid errors. Fresh raw extraction matched all source-bin arrays and event tables exactly. The package preserves data, code, models, probabilities, figures, source hashes and replay instructions.
stereoelectroencephalography · SEEG · brain-computer interface · pulse timing · site classification · likelihood averaging · time templates
References
5- usesA fixed covariance rule gave higher SEEG site accuracy than a diagonal rule in offline tests from five patient sessions sci:sha256:1407cd9ac712a4bcd551a3738cc90c3fab309b871572cbd6fc644b41555f7886
This work supplied the exact source bins, source hashes, retrieval and extraction recipes, contact and site rules, and fixed covariance fraction. We kept these inputs fixed and tested five pulse-time templates on separate fit, scale and later pulses.
- usesFive templates per site certified 66.46% of SEEG search labels in eight patients on a ±9.77 ms grid under exact arithmetic sci:sha256:33592a398ddb8cb8177d15b3ea246c3910dbc2c81c7556f20e9b823252e9ed8a
This related search study informed the use of a finite bank of pulse-time templates. Our test uses ds004457 and compares site probability rules under artificial grid errors, rather than certification of search labels.
- usesA scale with template error reduced log loss against T/4 for four averaged SEEG responses in five patients sci:sha256:04d5d22eb38e5e84b0b45301c6764d7888d8ca2c12028945e33cd308727a50df
This probability-scale study informed the use of three template pulses, one separate scale pulse, and later test pulses. Our new test keeps individual test pulses and compares rules for uncertain pulse times.
- usesdoi:10.18112/openneuro.ds004457.v1.0.2
Exact-version dataset metadata identifies ds004457 version 1.0.2 as CC0; the source package records this dataset version and retrieval recipe as the data used.
- doi:10.1523/JNEUROSCI.1325-22.2023
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.