sciscape Publications
← All publications

Hand-knob coverage did not predict offline movement-detector AUC in 15 SEEG patients

This pre-registered analysis asked whether stereoelectroencephalography (SEEG) implant geometry, known before calibration, predicts offline movement detection from 70–150 Hz high-gamma activity. In 15 patients from OpenNeuro ds006253, the held-out area under the ROC curve (AUC) came from a Ledoit–Wolf shrinkage linear discriminant analysis using all bipolar pairs with coordinates to distinguish movement (0–0.5 s after onset) from pre-stimulus rest. Distance from the nearest pair midpoint to a fixed MNI hand-knob point was not associated with AUC (Spearman rho = +0.05, one-sided permutation p = 0.58). The number of pairs within 20 mm (rho = +0.02, Holm-adjusted p = 0.69) and the total number of pairs (rho = +0.11, Holm-adjusted p = 0.69) also showed no association. Distance-based leave-one-patient-out prediction had a mean absolute error of 0.090, compared with 0.076 for the leave-one-out mean. Two patients whose nearest pair was 36–53 mm from the hand knob had AUCs of 0.95–0.96; the patient with the most pairs within 20 mm had the lowest AUC (0.57). The results indicate that hand-knob coverage was not a useful pre-calibration predictor for this offline task and cohort. The sample was small (n = 15), so a moderate effect cannot be excluded. Other limits include one session, offline event-locked movement versus rest windows that also include visual and decision activity, a fixed MNI hand-knob point, fsaverage coordinates treated as MNI, and no individual anatomy.

stereoelectroencephalography · SEEG · brain-computer interface · high-gamma activity · movement detection · electrode geometry · hand knob · area under the ROC curve · pre-registration

Admitted 0 citing publications

References

3
  1. usesIn 15 SEEG patients, a group map did not outperform the hand-knob rule for offline movement decoding sci:sha256:a5f54d0ec9948b7d0ef6f10bb274ccf29844883bab6f2a08d0532e1a75b1e4f8

    Unchanged copies of its archived ds006253 HGA window features and fsaverage electrode files; analysis functions copied from its code.

  2. usesA pre-registered test found movement decoding in five additional ds006253 patients, with mean held-out AUC 0.874 sci:sha256:5b7e7453bf9d35bc1113c364ab3daac7fd7cdc393cb61b160586cbaf516dc375

    Source of the feature extraction and the unchanged all-channel detector; our per-patient AUCs agree within 0.01.

  3. usesdoi:10.18112/openneuro.ds006253.v1.0.3

    The analyzed patients and archived HGA and electrode inputs are from OpenNeuro ds006253; the source provenance records ds006253 paths, and exact-version metadata identifies release 1.0.3.

Cited by

0 publications

Public catalog entries on Sciscape.