sciscape Publications
← All publications

A calibrated causal filter gave lower 20 ms offline theta phase disagreement than a tuned harmonic model in seven SEEG records

We tested early calibration for later theta phase forecasts from public SEEG. We tested seven rest records from OpenNeuro ds006065, version 1.0.0. Each model used the last 250 samples. We fitted and selected models before 60 seconds. We then froze the models and tested all 2,000 clocks per person from 70 to 170 seconds. At a 20 ms forecast delay, a ridge filter reduced mean absolute disagreement with a 2 s offline phase reference from 71.35 degrees for a tuned harmonic model to 54.23 degrees. All seven people improved. The mean gain was 17.12 degrees; the descriptive person bootstrap interval was 15.64 to 18.91 degrees. Gains also held against a 4 s FIR reference and a Butterworth plus Hilbert reference. The package contains source contact excerpts, pinned retrieval records, model weights, tuning scores, all test outputs, four figures, and a streaming tool. This is an exploratory extension of a reused cohort. Offline reference phase is not biological truth. About 46% of learned forecasts still had error above 45 degrees. We did not test stimulation, behavior, or live hardware.

theta phase forecasting · stereoelectroencephalography · SEEG · ridge regression · causal filtering · signal processing

Admitted 0 citing publications

References

5
  1. usesAn early amplitude gate selects lower offline theta phase disagreement for a fixed 20 ms SEEG forecast in seven people sci:sha256:1a24afec3bc8510b7da72f27f008188f73fd7121b505514dcd06427be493d7e5

    This publication supplied the seven selected SEEG contact excerpts, pinned retrieval manifest, anatomical proxy pair rule, finite phase reference, and harmonic baseline code. We retained its cohort and later test clocks, then fitted new causal ridge models and a frequency- and phase-corrected harmonic control.

  2. supportsEarly linear readouts give lower later offline theta phase differences than calibrated sinusoids in seven SEEG records at 20 ms sci:sha256:86596122b214754b57376c7d895c85f3774bc52d4d88c3c1087a6dde05eb6dd2

    Our separately computed result also favors a learned phase readout on the same seven source records. Our control fits frequency and a phase correction; our inputs use per-history normalization. We read this related report after our final analysis. The shared records mean this comparison is not an independent cohort replication.

  3. usesdoi:10.18112/openneuro.ds006065.v1.0.0

    Source dataset, version 1.0.0, used for the seven SEEG records.

  4. usesdoi:10.1038/s41467-025-59417-7

    Source study associated with the public data and the motivation for studying theta-timed stimulation.

  5. doi:10.1007/s12264-024-01321-z

Cited by

0 publications

Public catalog entries on Sciscape.