Gap selection gave two fewer later SEEG pulse matches than pair ranking in eight sessions with five calibration pulses, known pulse times, and r ≥ 0.8

This study tested whether five early electrical pulses could select a second SEEG recording pair that filled gaps in the first pair. Both rules used four contacts per site and known pulse times. The data came from OpenNeuro ds004696 version 1.0.1 and eight patient sessions. At r ≥ 0.8 over 20–500 ms, the gap rule gave 273 of 415 later pulse matches. Separate pair ranking gave 275. The equal-patient rates were 67.56% and 67.95%. The difference was −0.38 percentage points; the patient bootstrap 95% interval was −0.96 to 0.00 points. The sign-flip reference gave p = 0.50. The second pair changed at 22 of 83 sites. The early mean maximum correlation increased, but the later mean maximum correlation decreased. The package preserves exact trial products, all choices and pulse outcomes, figures, code, pinned source hashes, and replay instructions. A fresh complete-source extraction for one subject matched the inherited inputs exactly. This test does not establish equivalence, neural origin, live feedback benefit, or performance in a new cohort.

stereoelectroencephalography · electrical stimulation · brain-computer interface · recording-pair selection · pulse response · shape correlation

Admitted 0 citing publications

References

4
  1. usesTwo six-contact SEEG rules gave the same later site coverage in eight limbic sessions at a 0.8 shape cutoff over 20–500 ms sci:sha256:dd9e0beb891a72ef75ace93d83f1ba6b55e5102f224eb02b72a3054bb8d98e75

    Its fixed recording-contact budget comparison informed this study design. That work tested three pairs across sites and mean-waveform coverage. This study tests two pairs per site and individual pulses in the same cohort.

  2. usesIndividual pulse selection gave more later SEEG shape matches than selection by pulse means in eight sessions at r ≥ 0.8 sci:sha256:d10ab8b4c3d6f163e4725cadd1a9d3a48973f8213a028632f0e6408043c51370

    This study uses its exact centered pulse products, source metadata, extraction recipe, and first-pair leave-one-out correlation method. The new comparison selects a contact-disjoint second pair and tests individual later pulses.

  3. usesdoi:10.18112/openneuro.ds004696.v1.0.1

    The analysis uses OpenNeuro ds004696 version 1.0.1 as the source of the eight limbic SEEG sessions and pulse responses.

  4. doi:10.1523/JNEUROSCI.2201-22.2023

    This is the source study describing the dataset recordings and electrical stimulation.