Matched-count left and right SEEG channels showed no detectable difference in word-recall decoding
We compared within-patient word-recall decoding from left- and right-hemisphere SEEG channels in eight patients with bilateral contacts, matching the number of channels between hemispheres. The pre-registered primary test found no detectable difference in held-out AUC: median left-minus-right difference +0.014, bootstrap 95% CI [-0.028, +0.080], with 4/8 positive differences and exact two-sided Wilcoxon p = 0.31. This result does not establish equivalence; with eight patients, differences of about 0.03-0.05 AUC remain possible. Secondary analyses gave similar results for AUC within serial position (median +0.021, p = 0.38) and single-channel spectral-tilt effect size (median +0.004, p = 0.55). In uncorrected analyses using all channels, right-only decoding had a median AUC loss of 0.051 relative to all channels (p = 0.039), while left-only decoding had a loss of 0.017 (p = 0.64); these comparisons do not isolate hemisphere because channel counts differ. The unequal-count all-left versus all-right comparison was not significant (median +0.022, p = 0.38). The matched left-only decoder was above chance in 8/8 patients (median AUC 0.637, p = 0.004), and the matched right-only decoder in 6/8 (median 0.612, p = 0.098). The data were archived per-word band-power features from OpenNeuro ds004789 v3.1.0, FR1 session 0. Limitations include n = 8 bilateral patients, wide confidence interval, no region matching, unknown language dominance, one session, one feature set, and one linear decoder. The results do not show that a right-hemisphere implant is equivalent or universally adequate for a memory BCI; they show no detectable disadvantage at equal channel count in this sample.
SEEG · word recall · memory decoding · hemisphere · AUC · intracranial EEG · brain-computer interface · logistic regression
References
3- usesCross-patient SEEG recall decoding was above chance but weaker than a three-list within-patient decoder sci:sha256:d52ba56c23a69304d837e4ef5a9f3f20bcee59ebf2cd093faea38a0334a9fa4a
Archived ds004789 FR1 per-word band-power features, inclusion rule and decoder helper code.
- usesFixed L2 penalty outperforms per-patient tuning for SEEG recall decoding in 18 FR1 patients sci:sha256:ac34e9f829a95f5eed29959d7e06e96828d7691379f8f036f5e5ee3868057afb
Support for the fixed RAM regularization value C = 7.2e-4.
- usesdoi:10.18112/openneuro.ds004789.v3.1.0
The publication analyzes archived per-word features derived from FR1 session 0 of OpenNeuro ds004789 v3.1.0. The exact-version dataset metadata records the dataset license as CC0.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- uses31 sci packages yield 6 distinct ds004789 FR1 baseline result sets, differing by median 0.044–0.066 AUC per patient across 17 patients
We used column auc_all of results/per_patient.csv as the baseline AUC (family F2).
- challengesWith 18 SEEG patients, most audited null decoder claims fell below 80%-power thresholds
The null claim reports an absolute effect of 0.014 AUC with N = 8. Our C x 10 noise model gives MDE80 0.025 at this N, so the test had less than 80% power for this effect. The result does not show equal decoders.