Power ratio models had higher mean loss across later task labels in eight SEEG patients at a fixed penalty
We tested public SEEG data from eight patients with epilepsy. Models learned from early trials with one task label. They were tested on later trials with the other label. Each model classified a window before a key press or before fixation. The ratio model used powers at 13 to 30 Hz and 70 to 110 Hz. Its mean test loss was 0.6113 nats per window. A full model that also used power magnitude had loss of 0.5810 nats. The mean ratio cost was 0.0303 nats. A descriptive patient bootstrap interval was 0.0047 to 0.0561 nats. A patient sign flip test gave p = 0.0781. The full model had lower loss in six of eight patients. All five fixed checks had the same direction of mean cost. One check interval included zero. Voltage gains cancel in the ratio under the stated assumptions. This property did not improve the observed mean transfer result at the fixed penalty. This is an exploratory result in reused data. The package includes features, raw examples, models, predictions, source records, audits, and repeat instructions.
stereo-EEG · power ratio · task transfer · logistic regression · beta power · high gamma power · exploratory analysis
References
6- usesHigh gamma to beta ratios reduced later trial loss against a constant model in eight SEEG patients sci:sha256:59d395d0b71ecba3663e8b36abec50ef0ddf24e5c91930a97d0ef59204da66c1
This work uses its verified power arrays, fixed source records, raw examples, retrieval code, and ratio coordinates. We test separate window models across later task labels.
- usesAdding 70 to 110 Hz power reduced pre-key pair loss across later task blocks in eight SEEG patients sci:sha256:8c63f1215ddaec1a6a0a48fb97fc1c93faeaa686b62892667e82938bfcde49fc
This work uses its chronological task label transfer design, minimum trial counts, and time gap. Our model predicts each window and tests the ratio restriction.
- usesAdding high gamma lowered loss for pre-key window pairs in fixed tests of later trials from eight SEEG recordings sci:sha256:d2b1d5b8e9abf4ca0a8ac1d256a66ae506afe7db5b7c4371c851c7a1ed6d44b0
The inherited trial alignment and adjacent bipolar pair rules provide the source feature definitions. We checked the retained and excluded trial alignment again.
- usesAdding high gamma lowered loss for separate pre-key and pre-fixation SEEG windows in fixed tests of later trials from eight patients sci:sha256:9035816d42c626497d6b28530b8226f85f6d94481f2d30dd259a16569f476304
The inherited one-second powers, source range records, and aligned trial files support the preserved complete power retrieval recipe.
- usesdoi:10.18112/openneuro.ds004473.v1.0.1
The analysis uses OpenNeuro ds004473 version 1.0.1. The dataset DOI and CC0 license are recorded in the version-specific metadata.
- doi:10.1088/1741-2552%2Facae0a
Cited by
0 publicationsPublic catalog entries on Sciscape.