Median power lowers excess crossings near marked HFOs at matched calibration rates in eight sleep SEEG records
We tested whether a median of five short high-gamma power values reduces crossings near marked high-frequency oscillations (HFOs). We used OpenNeuro ds003498 version 1.1.1, with one sleep SEEG record from each of eight patients with epilepsy. The primary test used 88 exact-name bipolar pairs. Each method used a separate threshold from the first 120 s. Both had a 5% calibration crossing rate. On later data, mean power had a marked-minus-unmarked crossing excess of 14.85 percentage points. Median power had 7.46. The paired difference was -7.39 percentage points, with a 95% patient bootstrap interval from -11.95 to -2.80. Seven of eight patients had a negative difference. Median power increased unmarked crossings from 3.66% to 4.50%. The total test crossing rate changed little. A paired sine input test also showed a loss of response to short inputs. At fixed amplitude, 100 ms inputs added 63.30 percentage points for mean power and 17.70 for median power. These results show a feature tradeoff. The marks came from an automatic detector, and the data contain no intent or stimulation outcome labels. The package contains figures, code, power values, voltage samples, source hashes, a raw retrieval recipe, and reproduction instructions.
stereo-electroencephalography · high-frequency oscillations · high-gamma power · median filter · brain-computer interface · event detection
References
4- usesdoi:10.18112/openneuro.ds003498.v1.1.1
The analyzed recordings and event annotations came from OpenNeuro ds003498, release 1.1.1, pinned to Git commit d5aa5a24f3d4a8d49964fc88488aefa2b4dd9e44.
- usesdoi:10.6080/K06Q1VD5
This is the original CRCNS ieeg-1 dataset from which the OpenNeuro source data were obtained; the archived dataset description requests citation of the data set.
- supportsdoi:10.1038/s41598-017-13064-1
The source paper supports the stated electrode-type and HFO-mark context for the selected records. Its clinical outcome analysis is not repeated here.
- doi:10.1016/j.neuroimage.2022.118969
Background context for the use of high-gamma power in SEEG movement studies; no data or code from this paper were used.
Cited by
2 publicationsPublic catalog entries on Sciscape.
- usesAn amplitude gate raised the HFO mark share of simulated 6 Hz commands in eight sleep SEEG records
We reused pinned metadata, source hashes, retrieval code, and exact channel-name rules for eight depth-only sleep records. We checked fresh complete voltage downloads. Prior high gamma outcome tables were not input to the new 6 Hz gate analysis.
- usesSeparate-contact confirmation gave lower HFO crossing excess in four of eight sleep SEEG records at a 5% early crossing rate
We used the exact annotation mask, complete power arrays, source metadata, and retrieval routes from this publication. We retrieved and hash-checked all eight raw records again. All power arrays and labels matched exactly. The new study tests shared-contact and separate-contact joint confirmation. It does not supply an independent cohort for the prior median-power result.