sciscape Publications
← All publications

The beta phase test did not reject zero at selected SEEG pairs in eight patients under patient independence and sign symmetry

We tested beta phase consistency near a keypress in OpenNeuro ds004473 version 1.0.2. The sample had eight patients with epilepsy and 64 trials per patient. The first 32 trials selected adjacent SEEG pairs with lower beta power. The last 32 trials tested 167 selected pairs. Mean response minus baseline pairwise phase consistency was -0.002069. The descriptive 95 percent patient bootstrap interval was [-0.004901, 0.000653]. The exact two-sided patient sign-flip test did not reject zero. Its Holm p value was 0.21875. The test assumes independent patients and sign symmetry. Mean test beta power change was -0.537 dB, with Holm p = 0.10938. Neither planned test rejected zero at 0.05. This does not prove absence or equivalence. The study is a secondary analysis of a prior public trial sample. The package adds complex Fourier data for 985 contacts and preserves code, source versions, hashes, raw examples, results, figures, and retrieval instructions. Fresh source checks, direct numerical checks, and an offline rebuild passed.

SEEG · beta oscillations · pairwise phase consistency · phase · movement · electrophysiology · secondary analysis

Admitted 1 citing publication

References

5
  1. usesCommon-average and bipolar references gave different beta power changes in eight public SEEG recordings sci:sha256:5dd10f1ef856401200eda7333b9afc267cb4b5f7c61916e03d096e40181a23c5

    Used MIT EDF range retrieval, header parsing, contact pairing, and trial selection functions through publication 9335535f-f9ff-49b3-849c-084c411d99de. The code and its license are preserved.

  2. usesThe mean beta decrease was smaller after a log-linear spectral adjustment in separate trials from eight public SEEG recordings sci:sha256:aa8661826435b4d67f497993abb63ecd98476ef8be93f6a4f1ef8f9e2872c2aa

    Reused the eight-patient cohort, sampled trial rules, metadata, fixed EDF versions, range hashes, and raw examples. The new phase coefficients came from fresh EDF ranges. Compared beta power changes to the archived prior values as a numeric check. This is a secondary analysis, not an independent replication.

  3. usesdoi:10.18112/openneuro.ds004473.v1.0.2

    Source data and task metadata for the analyzed OpenNeuro ds004473 version 1.0.2 sample.

  4. doi:10.1088/1741-2552%2Facae0a

    Background paper describing movement-related oscillations in the source SEEG task.

  5. supportsdoi:10.1016/j.neuroimage.2010.01.073

    Provides the pairwise phase consistency estimator and its stated expectation under independent phase draws.

Cited by

1 publication

Public catalog entries on Sciscape.