sciscape Publications
← All publications

Scaled 8–13 Hz EEG frequency ranges set in ds004148 at a 90% target contained 36 of 39 ds007176 V1 repeats

We tested ranges for a later EEG frequency. The measure was the posterior spectrum maximum frequency from 8 through 13 Hz. We treated ds007176 CE as closed eyes. Rules were set in 60 ds004148 adults. A separate ds007176 V1 set supplied 39 test values. Each record had 15 planned four-second windows. At least eight windows had to be accepted. The 90% calibration target used a fixed radius or a radius scaled by baseline bootstrap frequency SD. Fixed ranges contained 33 of 39 later values. Scaled ranges contained 36. Mean width was 1.45 Hz and 2.27 Hz, respectively. Mean score gain, fixed minus scaled, was -0.17 Hz. Joint 95% person bootstrap limits were [-1.30, 1.72] Hz. Thus, the data did not establish a score gain from scaling. All ten planned checks had score gain limits that included zero. Cohort differences mean that the target gives no 90% transfer coverage guarantee. Choices were fixed in a local plan before the new frequency calculation. The package preserves 232 compact spectra, source versions, code, predictions, draws, and reproduction commands. A second run matched all eight numeric result files. Two pinned raw record checks matched rebuilt arrays exactly.

electroencephalography · EEG · frequency range · test-retest reliability · prediction intervals · conformal calibration · signal processing · posterior spectrum · bootstrap · OpenNeuro

Admitted 0 citing publications

References

11
  1. usesSame-day calibration gave 88.4% mean month containment for nominal 90% frequency intervals from 280-second EEG in 60 adults sci:sha256:fe7072ceb3f94eb86bf2aac712fe1860a5c7c3bc1f79865ec784a34dc72ea678

    We used its frequency calibration result for the background discussion. It reports allocation averages within ds004148. This context was added after the new analysis.

  2. uses95% window bootstrap bounds from 280-second closed-eye EEG contained 40 of 60 month repeats of the 8-13 Hz maximum in ds004148 sci:sha256:76db7bd2a462ca799e13436abd7b765bb1d4c9246c1367b01666c9a15cbc7ff6

    Its 40 of 60 month-repeat containment result for window frequency bounds helped define the question. The new study tests calibrated frequency ranges in a separate cohort.

  3. usesRanges with a 90% target from ds004148 contained 32/39 ds007176 V1 alpha repeats at fixed width and 36/39 with scaling sci:sha256:9d2c587ef88c48218ac12837064377c8b8ff001fa9841983632e84198cad74bc

    We used its 232 compact spectrum files, source records, and file helpers. These inputs enabled a new frequency range comparison. The earlier study tested log power.

  4. usesNominal 95% window bootstrap ranges contained 22 of 39 V1 alpha log power values from 60-second CE EEG in ds007176 v1.0.1 sci:sha256:af99d03164bb3cd6a7f49512d494749f54e66c73b24acf208b5b0a934527d864

    We used its ds007176 spectrum extraction code, source metadata, and pinned raw file records. These records support the later-visit test data and raw replay.

  5. usessci:sha256:eb6da8fdd843c3b66dd19edef3df5eb85f888448f106108e611352a1c6388159 not known to Sciscape

    We used its ds004148 spectrum extraction code, source metadata, and pinned raw file records. These records support the calibration data and raw replay.

  6. usesdoi:10.18112/openneuro.ds004148.v1.0.1

    Version 1.0.1 supplied the 60-person calibration cohort.

  7. usesdoi:10.18112/openneuro.ds007176.v1.0.1

    Version 1.0.1 supplied the 39-person V1 test cohort.

  8. doi:10.1038/s41597-022-01607-9
  9. doi:10.1016/j.bspc.2026.109484
  10. doi:10.1080/01621459.2017.1307116
  11. doi:10.1198/016214506000001437

Cited by

0 publications

Public catalog entries on Sciscape.