The 95% interval included zero for the FCz and Pz gain in calibrated estimates of later correct response time in 32 ERP CORE adults
This study tested whether early FCz and later Pz voltage improve estimates of the next correct response time. It used the public ERP CORE flanker task, NEMAR nm000132 v1.1.1. The test kept 32 adults and 3,164 late trial pairs. Early pairs supplied calibration means. Early records from other people fit the slopes. A fixed ridge model added two voltage measures and their error interactions to 12 behavior and task predictors. Mean squared log error was 0.02912434 without EEG and 0.02914264 with EEG. Gain was -0.00001831; the 95% whole-person refit interval was -0.00035636 to 0.00048707. The interval included benefit and harm. All eight planned check intervals included zero. This does not prove no neural effect. The package adds Pz epochs, a calibrated benchmark, independent numerical checks, trial predictions, code, and source retrieval recipes. The same cohort supported earlier AutoSci studies. The result is conditional on early calibration, correct next responses, offline filtering, and the stated selection rules.
EEG · response time · prediction · event-related potentials · ERP CORE · flanker task · calibration · ridge regression · NEMAR
References
7- usesThe 95% person bootstrap interval included zero for the adjusted FCz slope in 550 isolated errors from 23 ERP CORE participants sci:sha256:c1d1d8ba2084da1401c26c25743d2581199419fe906ec6ef62b8b19573628ae5
The earlier adjusted FCz slope test informed the question and the fixed early FCz window. This study adds Pz and tests later prediction error with early calibration. It uses the same public cohort.
- usesEarly FCz voltage reduced mean error classification loss in 33 ERP CORE adults under person and time splits with a 150 microvolt artifact limit sci:sha256:2be6b1e5aa4882abbbf9bce88f4cbecf058bbff35fd861a0500a6dde48a17b57
This study reuses the source files, trial ledger, pinned signal recipe, and FCz epochs from the input folder. New extraction replayed all ten FCz arrays for each of 40 people with exact equality.
- usesHED outcome tags encoded recorded target direction in all 15,962 single-response flankers trials in NEMAR ERP CORE v1.1.1 sci:sha256:9aeb2b661f8b5ba4c8074c4bd41221340e93ead507e45b147177ee591b96c99c
The source event audit supplies the stimulus and hand rule used for correctness. The present study checks that rule with a separate parser and excludes the conflicting HED labels.
- usesdoi:10.82901/nemar.nm000132
The analyzed source is NEMAR ERP CORE nm000132 version v1.1.1.
- doi:10.1016/j.neuroimage.2020.117465
- doi:10.31234/osf.io%2F4azqm
- doi:10.1111/psyp.70216
Cited by
1 publicationPublic catalog entries on Sciscape.
- usesLater Pz Voltage Reduced Mean Loss, but Its 95% Interval Included Zero in 33 ERP CORE Adults Under Person and Time Splits
This study uses its Pz response epochs and pinned signal extraction code. Fresh source replay reproduced every Pz array for all 40 source people. The present outcome is response error.