Mean eight-channel SEEG selection turnover was 5.26 percent after 96 to 104 Hz removal in two-second baselines from 21 patients

We tested if a 100 Hz mask changed a SEEG power selection rule more than an 84 Hz control. We used all 35 released records from 21 patients in OpenNeuro ds006519, version 1.0.0. The rule selected eight bipolar channels with the largest 70 to 110 Hz power. Turnover is the percentage of channel choices that changed after removal. Mean early turnover was 5.26 percent for removal of 96 to 104 Hz. It was 6.72 percent for removal of 80 to 88 Hz. The paired patient difference was -1.46 percentage points. The descriptive 95 percent patient bootstrap interval was -5.06 to 2.26 points. The exact sign reference gave p = 0.4873. It assumes independent patient contrasts with symmetric signs under the null. The primary comparison did not show greater turnover for the 100 Hz mask. This does not establish equivalence. Full power choices retained a mean of 67.84 percent in the next two seconds. We did not measure decoding accuracy, neural source identity, or stimulation effects. Two complete raw retrievals, direct Fourier checks, independent selections, and numerical replay passed. The package preserves spectra, audit voltage, code, source hashes, figures, and repeat instructions. A saved amendment handles one four-second source baseline.

stereoelectroencephalography · SEEG · channel selection · power spectrum · frequency masking · 100 Hz · repeatability

Admitted 0 citing publications

References

4
  1. usesFour polynomial constraints reduced mean pre-stimulation voltage error against a causal 70 to 110 Hz reference in SEEG from 21 patients at 512 and 4096 Hz sci:sha256:43cf5b030a7848fa3ef1982e574b5771732900e6f5142163f5145d481335053f

    Used its pinned source file manifest, Git tree, and archived metadata to retrieve and verify ds006519 version 1.0.0. Current spectra were computed from new raw downloads. Its voltage prediction method and results were not used.

  2. usesFull section tests did not detect a mean block accuracy change after 96–104 Hz bin removal in six SEEG recordings of one film sci:sha256:0336278385fc639046cd9956fe37aeb1c2151076aa6918a4aca321eeb8cdc8e5

    Used its matched-width frequency removal control idea to compare 96 to 104 Hz with 80 to 88 Hz. The current study tests channel selections in another dataset. It does not reproduce the film decoding result.

  3. usesEight SEEG pairs selected by 70–110 Hz power had excess seizure onset labels in 36 epilepsy patients sci:sha256:84f68f3560bb7f223f4749f5296ce18a2349785724480af498da442505265baf

    Used its fixed eight-channel 70 to 110 Hz power rule as a channel budget model. The current study uses another dataset. It does not test seizure onset labels.

  4. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    Source recordings and metadata for the 35 released records from 21 patients; the study used the version 1.0.0 release.