In OpenNeuro ds003876, SSI did not outperform 1–45 Hz power in identifying clinical seizure-onset channels
We re-implemented the interictal source-sink index (SSI) from the published description and compared it with log 1–45 Hz power in 30 patients from four centers in OpenNeuro ds003876. We analyzed one 60-s interictal segment per patient (3,270 good SEEG channels, including 216 clinical seizure-onset-zone [SOZ] channels). In the prespecified, per-window z-scored analysis, mean per-patient SSI AUC was 0.31 (95% CI 0.24–0.38; 5/30 patients above 0.5; Holm-adjusted p = 0.00015), indicating lower SSI at SOZ channels. Power AUC was 0.73 (0.66–0.80), and the mean SSI-minus-power AUC difference was −0.42 (−0.53 to −0.31; Holm-adjusted p = 0.0001). In a post hoc analysis without z-scoring, SSI AUC was 0.58 (0.51–0.64; p = 0.031), but remained below power and showed no SOZ separation after linear power control (residual AUC 0.46, p = 0.32; the z-scored residual AUC was 0.46, p = 0.28). The SSI–power correlation changed from −0.46 (−0.56 to −0.34) to +0.45 (0.33–0.56) without z-scoring, so the direction of the SSI effect depended on normalization. This re-implementation did not reproduce the reported AUC of about 0.77. Interpretation is limited by unspecified implementation details, one arbitrary 60-s segment per patient, clinical SOZ labels, and less well-determined least-squares matrices in some windows. The source files, code, results, segment hashes, URLs, and other provenance are preserved in the package.
source-sink index · intracranial EEG · seizure onset zone · epilepsy · signal power · OpenNeuro · replication
References
2- supportsIn 36 HUP SEEG patients, the source-sink index marked SOZ pairs but added no information beyond broadband power sci:sha256:029d18f990f9cba099ac924662f5c2dd611adbd56e35dea06b391536eeda6a71
In a different dataset (ds003876, 4 centers, CAR, 500-ms windows), we also found that the SSI tracks channel power, that z-scoring reverses its SOZ effect (AUC 0.31 vs 0.58 without z-scoring), and that SSI gives no SOZ information after power control (residual AUC 0.46 in both versions).
- usesInterictal SEEG power marks seizure onset zone pairs across four centers, while the exponent effect is absent within shafts sci:sha256:93b08af9874ce22ced4be29280c89690cfc400d9efa462916f5aaaff91b4b87e
We used its EDF range-read helper code (adapted), its file-selection rule (selected_files.json), participants.tsv and the S3 listing of ds003876. Our CAR 1-45 Hz power AUC (0.73, 30 patients) agrees with its bipolar 1-45 Hz power result (0.72).