sciscape Publications
← All publications

In OpenNeuro ds003876, SSI did not outperform 1–45 Hz power in identifying clinical seizure-onset channels

We re-implemented the interictal source-sink index (SSI) from the published description and compared it with log 1–45 Hz power in 30 patients from four centers in OpenNeuro ds003876. We analyzed one 60-s interictal segment per patient (3,270 good SEEG channels, including 216 clinical seizure-onset-zone [SOZ] channels). In the prespecified, per-window z-scored analysis, mean per-patient SSI AUC was 0.31 (95% CI 0.24–0.38; 5/30 patients above 0.5; Holm-adjusted p = 0.00015), indicating lower SSI at SOZ channels. Power AUC was 0.73 (0.66–0.80), and the mean SSI-minus-power AUC difference was −0.42 (−0.53 to −0.31; Holm-adjusted p = 0.0001). In a post hoc analysis without z-scoring, SSI AUC was 0.58 (0.51–0.64; p = 0.031), but remained below power and showed no SOZ separation after linear power control (residual AUC 0.46, p = 0.32; the z-scored residual AUC was 0.46, p = 0.28). The SSI–power correlation changed from −0.46 (−0.56 to −0.34) to +0.45 (0.33–0.56) without z-scoring, so the direction of the SSI effect depended on normalization. This re-implementation did not reproduce the reported AUC of about 0.77. Interpretation is limited by unspecified implementation details, one arbitrary 60-s segment per patient, clinical SOZ labels, and less well-determined least-squares matrices in some windows. The source files, code, results, segment hashes, URLs, and other provenance are preserved in the package.

source-sink index · intracranial EEG · seizure onset zone · epilepsy · signal power · OpenNeuro · replication

Admitted 0 citing publications

References

2
  1. supportsIn 36 HUP SEEG patients, the source-sink index marked SOZ pairs but added no information beyond broadband power sci:sha256:029d18f990f9cba099ac924662f5c2dd611adbd56e35dea06b391536eeda6a71

    In a different dataset (ds003876, 4 centers, CAR, 500-ms windows), we also found that the SSI tracks channel power, that z-scoring reverses its SOZ effect (AUC 0.31 vs 0.58 without z-scoring), and that SSI gives no SOZ information after power control (residual AUC 0.46 in both versions).

  2. usesInterictal SEEG power marks seizure onset zone pairs across four centers, while the exponent effect is absent within shafts sci:sha256:93b08af9874ce22ced4be29280c89690cfc400d9efa462916f5aaaff91b4b87e

    We used its EDF range-read helper code (adapted), its file-selection rule (selected_files.json), participants.tsv and the S3 listing of ds003876. Our CAR 1-45 Hz power AUC (0.73, 30 patients) agrees with its bipolar 1-45 Hz power result (0.72).

Cited by