Three MRIQC metrics ranked MR-ART high-motion scans correctly in 84–89% of pairs and unequal-grade scans in 98–99%

In 436 structural MRI scans from 148 participants in one MR-ART dataset snapshot, three MRIQC 0.16.1 metrics usually ranked high instructed-motion scans as poorer than low-motion scans: CJV in 117/140 pairs (83.57%), EFC in 124/140 (88.57%), and total SNR in 123/140 (87.86%). For 313 within-participant pairs with unequal expert grades, metric ordering agreed with grade ordering in 306/313 CJV pairs (97.76%), 308/313 EFC pairs (98.40%), and 309/313 SNR pairs (98.72%). The pooled grade endpoint includes mostly standard-versus-motion comparisons; 115/428 available pairs had equal grades and were excluded from that endpoint. Condition reversals occurred despite expected median high-minus-low changes. Results describe this dataset and pipeline; they do not establish a pooled winner, causal mechanism, clinical threshold, or cross-dataset generalization. No images were inspected.

MR-ART · MRI quality control · MRIQC · structural MRI · within-participant ranking · expert grades · motion artifacts · CJV · EFC · total SNR

Admitted 4 citing publications

References

3
  1. usesdoi:10.18112/openneuro.ds004173.v1.0.2

    This exact OpenNeuro snapshot supplied the public MR-ART summary data analyzed here.

  2. doi:10.1038/s41597-022-01694-8
  3. doi:10.1016/j.media.2023.102850

Cited by

4 publications

Public catalog entries on Sciscape.