A two-moment beta test gave 53 percent mean relative tail error at a 0.1 percent level in 700 pairs of 2-second SEEG beta windows under an independent phase null
We tested a correlation rule that matches variance and excess kurtosis in a measured spectrum. We used 700 fixed channel pairs from 35 public recordings in 21 people. The source was OpenNeuro ds006519 version 1.0.0. Each input was a 2-second prestim SEEG beta window. The null had independent uniform phases and fixed Fourier magnitudes. At the planned two-sided 0.1 percent level, mean absolute relative tail error was 53.47 percent. A variance-matched Pearson rule gave 46.23 percent. The paired difference was +7.24 percentage points, with a person bootstrap interval from -22.90 to +54.28. The primary test did not show a mean improvement. The two-moment rule gave lower errors in all 21 people at the secondary 1 and 5 percent levels. A measured peaked spectrum gave a 3.47 percent null call rate at a 0.1 percent threshold. We provide a full-spectrum numerical tail tool, a proof that equal variance can give different tails, and three figures. Fresh source reconstruction, continuous integration, and seeded replay checks passed. Two independent phase simulations supplied 14 million controls. The package preserves code, provenance, compact spectra, primary scores, extra counts, and reproduction instructions. The result is a conditional calibration benchmark. It does not establish better decoding or safer brain stimulation.
stereoelectroencephalography · SEEG · beta band · correlation · null calibration · phase randomization · tail probability · spectral analysis · brain-computer interface · numerical inversion
References
3- usesNative sample counts give excess correlation calls under an independent phase null in 2-second SEEG beta windows from 21 participants sci:sha256:57eed8340807f9a6c0ee0a20be060749718a0560d83b328d5e823b65095231f9
Used the fixed 700 pair set, 35 beta coefficient arrays, pinned metadata, extraction code, and retrieval recipe. New seeds and tail calculations test whether two spectrum moments improve strict null calibration.
- usesA paired test did not detect increased high-gamma drift in annotated post-stimulation windows from 21 SEEG participants sci:sha256:0eb1cda13cce113a7a1fe70466917eeb0278c662b2155ce27ee9d36ce7636489
Used its pinned raw file manifest and BrainVision header reader through the phase-null source package. These files enabled a verified fresh reconstruction of every beta input. The stimulation-drift contrast was not tested.
- usesdoi:10.18112/openneuro.ds006519.v1.0.0
The publication analyzes fixed 2-second prestimulation SEEG windows from this exact dataset release; the source record identifies version 1.0.0 and CC0.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.