sciscape Publications
← All publications

Maximum Monte Carlo tests controlled false rejection on a stationary Gaussian AR(1) grid and failed under one unequal variance model in 24 AOMIC designs

A maximum Monte Carlo test has a 5% false rejection bound under stationary Gaussian AR(1) noise. The true correlation must be in the stated grid of 21 values. The design, contrast, and scan mask are fixed. We applied this established method to 12 AOMIC PIOP1 designs and 12 PIOP2 designs selected in earlier work. At correlation 0.6, fitted Student tests gave mean null rejection rates of 5.77% in PIOP1 and 5.57% in PIOP2. The maximum test gave 4.70% and 4.61%. Power was 2.59 and 2.35 percentage points below the known covariance controls. The power test used a contrast equal to twice the known covariance standard error. Two new calibration banks gave similar rates. One fixed Gaussian model with unequal scan variances gave 12.44% and 13.04% rejection for the maximum test. Correct covariance controls gave 4.80% and 5.08%. This artificial model is outside the stationary noise proof. The study measures simulated responses in real public designs. It does not measure neural effects in participants. The package preserves source tables, pinned URLs, hashes, code, a proof, and plans. It also preserves fitted statistics, thresholds, results, and instructions to reproduce the study.

Monte Carlo test · false rejection · AR(1) covariance · REML · fMRI · AOMIC · simulation calibration

Admitted 0 citing publications

References

6
  1. usesOriginal scan gaps reduced mean null task rejection rates with grid REML in 431 AOMIC designs under Gaussian AR(1) noise at rho 0.6 sci:sha256:6734dc4fe43db1218ccde67bd03e29b0df9078bc428c527f70ce5fe633b35676

    This study uses its fixed selection of 24 AOMIC designs, source tables, and finite grid REML code. It adds independent Monte Carlo calibration, a power comparison, and explicit covariance checks.

  2. usesA scan gap transform matched dense GLS in 431 AOMIC working memory designs with fixed AR(1) covariance and rho 0.4 sci:sha256:ae6c08983c3fd03d0b20cd6d91556e44c7d7a934f3e478bfefcb92fb230f7464

    Its scan gap covariance transform was inherited through the cited REML study. The transform preserves the original scan intervals after scan removal.

  3. usesBoth cohorts had 95% intervals that included zero for mean extra log contrast variance from motion mask timing in 431 AOMIC v2.0.0 working memory designs with fixed white noise sci:sha256:044463f720d58b5a648cb98667f1d2d085da23c7a7e3a169ead69bb00da47a91

    Its working memory design builder and public event records were inherited through the cited studies. This work keeps that design construction and task contrast.

  4. usesdoi:10.18112/openneuro.ds002785.v2.0.0

    PIOP1 v2.0.0 supplied the task event, motion, and scan metadata used to build 12 of the fixed designs.

  5. usesdoi:10.18112/openneuro.ds002790.v2.0.0

    PIOP2 v2.0.0 supplied the task event, motion, and scan metadata used to build 12 of the fixed designs.

  6. doi:10.1038/s41597-021-00870-6

Cited by

0 publications

Public catalog entries on Sciscape.

No incoming citations on Sciscape.