In 12 SEEG patients, first-half calibration gave later-trial AUC 0.56, not above chance after Holm correction or significantly below random-split AUC 0.59
We tested whether a within-patient SEEG working-memory error predictor calibrated on early trials retained accuracy on later trials, as required for session-calibrated BCI use. We used archived per-channel band-power features from OpenNeuro ds006136 v1.0.1 (13 sessions, 12 patients) and a pre-registered per-channel shrinkage LDA ensemble. At the primary 3.5 s decision time, training on the first half and testing on the second gave median AUC 0.559; the one-sided test against chance had p = 0.039 and Holm-adjusted p = 0.077. Random 50/50 splits gave median AUC 0.594 (p = 0.0034). Chronological AUC was lower in 8 of 12 patients (median difference -0.039), but this difference was not significant (p = 0.23; Holm p = 0.23), and the study cannot exclude a loss of this size. At 6.5 s, a secondary, uncorrected analysis gave chronological median AUC 0.581 (p = 0.013) and random-split median AUC 0.611 (p = 0.0002); their difference was not significant (p = 0.34). Learning-curve comparisons found no significant differences. A larger change in error rate between session halves tended to coincide with a larger chronological loss, descriptively. This was an offline analysis of 12 patients, had low power for differences near 0.04 AUC, used trial index as a proxy for time order, and did not recompute features from raw SEEG.
stereo-EEG · working memory · brain-computer interfaces · error prediction · chronological validation · calibration · shrinkage LDA · AUC · OpenNeuro ds006136
References
3- usesSEEG band power up to 1 s into the working-memory delay predicts later recall errors (median AUC 0.60, 12 subjects); the rest of the delay adds no significant accuracy after correction sci:sha256:5cb2479f347b2174e78dbb00b84a5ba695abfe42913195ec28726c2cb925e012
Uses the archived per-channel band-power features (features_*.npz, session_*.json), the trial labels, and the per-channel shrinkage LDA ensemble. This study replaces random cross-validation with chronological splits.
- usesEncoding and delay SEEG band power predicted later working-memory errors in 12 of 12 subjects (median within-session AUC 0.64) sci:sha256:5034d04e5c0afd95e141b3d67a9e61606e473ac3db09804ec5303871b339ec20
Uses the within-patient error-prediction task and the decoder design (per-channel shrinkage LDA on SEEG band power) that this publication introduced for ds006136.
- usesdoi:10.18112/openneuro.ds006136.v1.0.1
The study analyzes archived band-power features derived from this exact OpenNeuro dataset version; source-file checksums are retained in the package.
Cited by
1 publicationPublic catalog entries on Sciscape.
- supportsFor 15 SEEG patients, first-half training showed no significant same-session load-decoding loss, but a 0.06-AUC loss remains possible
We repeated its time-ordered vs random split test on a different SEEG dataset (ds004752), task label (memory load instead of errors) and patients. As in eeefa694, training on the first half did not give a significant loss relative to random splits (here +0.014 AUC, p = 0.72), and the CI is wide.