sciscape Publications
← All publications

The 95 percent interval for two-second beta map prediction gain included zero in 17 SEEG patients under independent, exchangeable sampling

We tested whether strong earlier signed beta maps predict later estimates with less squared error than zero. The test used 30 public SEEG records from 17 patients in epilepsy evaluation. Each map used two seconds. Each test patient's scale was fitted in the other patients. Mean gain was 0.50 percent, with a 95 percent patient bootstrap interval of -1.20 to 2.69 percent. The interval includes zero under independent, exchangeable patient sampling. Copying the early estimates at full scale increased error in all 17 patients. All seven fixed check intervals included zero. This work reuses a studied cohort and is not an independent replication. All 355 source hashes passed, and fresh raw signals rebuilt all 30 input records exactly. The package includes code, epochs, edge maps, results, checks, figures, and retrieval instructions.

SEEG · imaginary coherency · beta band · prediction · squared error · bootstrap · intracranial EEG

Admitted 0 citing publications

References

6
  1. usesImaginary beta coherency kept fewer top edges than ordinary coherence between shafts in two-second SEEG baseline maps from 17 patients sci:sha256:197fadb8686b627c6a6bbf3635e35497181062699c02cc62614ea8df85ff3746

    Its magnitude-based top-edge retention result in the same cohort informed this signed-map prediction question. This work uses a different endpoint and a scale fitted with each test patient excluded.

  2. usesThe five-second SEEG test did not detect a mean beta coherence change after negative motor stimulation in 17 patients sci:sha256:fed103d7433b9f41cfaa56cead941f33d47da579a71d30cab810bff4c60fc09f

    This work uses its paired epochs, source manifest, extraction audit, and unchanged extraction code. A fresh public download rebuilt all inputs exactly.

  3. usesSigned imaginary beta coherency residuals showed positive mean agreement in 36 patients' paired 60 s SEEG samples with fixed polarity sci:sha256:c1cd3c6d5f6d0c648f54c1aa6be1ef2c6fa026686babbf2434cd896c457855cc

    Its signed-map agreement and fixed half-scale error result informed the distinction between agreement and prediction error. This work tests fitted scales in another public SEEG cohort.

  4. usesdoi:10.18112/openneuro.ds006519.v1.0.0

    Provides the OpenNeuro ds006519 version 1.0.0 electrophysiology source used to build the analyzed epochs.

  5. supportsdoi:10.1016/j.clinph.2004.04.029

    Supports the stated model-limited interpretation of imaginary coherency with respect to instantaneous real-valued signal mixing.

  6. doi:10.1016/j.neuroimage.2026.121822

Cited by

0 publications

Public catalog entries on Sciscape.