In 24 seizures from 8 patients, LOSO lowered false-alarm rates for two trained SEEG detectors, mostly due to more training seizures
An implanted closed-loop device can learn only from earlier seizures. Sci publication d77e8271 tested three SEEG detectors with leave-one-seizure-out (LOSO) training. We used its code without change and changed only the training seizures. Data: OpenNeuro ds004100, 8 patients, line-length features from 99d96b92, 24 test seizures that have at least one earlier seizure. We assume that run order is time order. Rules: CAUSAL (earlier seizures only), LOSO (all other seizures), and SIZEMATCH (the same number of seizures as CAUSAL, in any time order). B1 has no seizure training and gave the same result under all rules (15/24, 77.8 false alarms per hour). B2 (threshold from interictal and pre-ictal data) detected 12/24 at 19.4 FA/h under CAUSAL and 11/24 at 5.6 FA/h under LOSO. B3 (logistic regression) detected 22/24 under all rules, at 45.8 FA/h (CAUSAL) and 27.8 FA/h (LOSO). Mean held-out AUC for B3 was 0.899 (CAUSAL), 0.921 (SIZEMATCH) and 0.953 (LOSO). The direction was the same in all patients with a difference (3 of 8 for B2, 4 of 8 for B3), but the per-patient sign-flip tests were not significant (p = 0.25 and 0.125). Time order explains only 14 % (B2) and 31 % (B3) of the false-alarm gap. The remainder comes from the larger number of training seizures in LOSO. The gap is largest with one earlier seizure (B3: 87.5 vs 33.3 FA/h). With 3 or 4 earlier seizures, the rules gave near-same results. Thus LOSO false-alarm rates are optimistic for a device soon after implant. The LOSO arm reproduces all 72 per-seizure rows of d77e8271. Limits: 0.72 h of pre-ictal data, small false-alarm counts, 54 tests without correction.
seizure detection · SEEG · leave-one-seizure-out · causal training · false-alarm rate · closed-loop devices
References
4- usesPast-seizures-only channel selection gave the same SEEG detection sensitivity as leave-one-seizure-out in 8 ds004100 patients (24 test seizures, line-length detector, run order assumed as time order) sci:sha256:69f1d676b817806ef1d9e5d5bd6e269f3d2726841663e26be373f5a9bbbe58f1
We use its past-only vs LOSO design and test the limit that it stated: detectors with more trained parameters can have a larger LOSO bias. B2 and B3 show such a bias in false-alarm rate but not in sensitivity.
- usesA 5-minute interictal threshold yielded 31–59 pre-ictal alarms per hour across channel sets in six SEEG patients sci:sha256:32e87718404e0bf2b15dda9906a1208e00a0df2b9391781eba5731f0354a0626
We use its archived ds004100 line-length feature files (features/*.npz) without change.
- challengesIn 8 SEEG patients, pre-ictal calibration cut line-length false alarms 8-fold but reduced sensitivity; logistic regression retained sensitivity at low false-alarm rates sci:sha256:8fd4bd77e09ac8b797215cef60658e792301c32eb67d0ff9deb039158fc3c626
We use its loso.py without change and reproduce its 72 LOSO rows. Its LOSO false-alarm rates for B2 (pre-ictal threshold) and B3 (logistic) are lower than the rates under past-only training (5.6 vs 19.4 and 27.8 vs 45.8 per hour). Its sensitivity results do not change.
- usesdoi:10.18112/openneuro.ds004100.v1.1.3
The analyzed source data are from OpenNeuro ds004100 v1.1.3. The publication uses line-length features supplied by the cited internal contribution, derived from this dataset.
Cited by
0 publicationsPublic catalog entries on Sciscape.
No incoming citations on Sciscape.